User Manual SIPLACE Head Care Station - - 第57页

5 Working with the HCS 5.2 Head verification process User Manual SIPLACE Head Care Station 10/2017 57 Fig.51: Refitting the cover ► Fit the cover back on. ► Make sure that the actuator snaps back into the safety switch…

100%1 / 76
5 Working with the HCS
5.2 Head verification process
56 User Manual SIPLACE Head Care Station 10/2017
Fig.48: Removing the cover
Connections at the back:
Grab the knob(1) and pull the protective
cover(2) with the actuator(3) upwards out of the
safety switch(4).
Fig.49: Connecting the flat ribbon cablesr
Connect the flat ribbon cables(3) of the Board
Adapter-LP C700B-HCSII[03087842-xx](1) to
the Board Adapter-LP CPP/CP20-HC-
SII[03087843-xx](2).
Fig.50: Setting the voltage
For C&P20x heads, set the switch(1) to 40V.
For CPP heads, set the switch(1) to 150V.
5 Working with the HCS
5.2 Head verification process
User Manual SIPLACE Head Care Station 10/2017 57
Fig.51: Refitting the cover
Fit the cover back on.
Make sure that the actuator snaps back into the
safety switch(1).
Fig.52: Connecting the hoses
Connect the hose for compressed air supply or
vacuum to the head top(1).
Connect the hose for compressed air supply to
the pressure regulator valve (PRV)(3).
Connect the hose(2) for the exhaust air to the
head.
For information on the correct pneumatic connections,
see 3.1.6.2 "Pneumatic connections for the
heads" [}41].
Fig.53: Opening the valves
Open the main valve for the compressed air sup-
ply(1) at the back of the head unit.
Open the respective valves(2) for the com-
pressed air supply to the head.
If required, open the valve(3) for the vacuum
supply to the head.
 CAUTION!
Risk of injury due to loose pneumatic hoses!
Always ensure the valves of the pneumatic con-
nections for the heads are closed before switch-
ing on the main valve for compressed air.
.
For information on the correct pneumatic connections,
see 3.1.6.2 "Pneumatic connections for the
heads" [}41].
5 Working with the HCS
5.2 Head verification process
58 User Manual SIPLACE Head Care Station 10/2017
Fig.54: Adjustment wheel and manometer
Pull off the cap(1) of the adjustment wheel.
Turn the adjustment wheel until the mano-
meter(2) shows 4.8 bar.
5.2.1.2 Setting up a P&P module
Fig.55: P&P module
1 Hose for compressed air supply to head 2 Exhaust air hose
3 Hose for compressed air supply to PRV 4 Stopper for P&P modules
5 Placement head with calibration nozzles 6 Flat ribbon cable connecting head inter-
face and head adapter
7 Flat ribbon cable to the head interface
NOTICE
Calibration nozzle
For the head verification, the head must be equipped with calibration nozzles.