5 Working with the HCS 5.2 Head verification process User Manual SIPLACE Head Care Station 10/2017 69 5.2.6.4 Inserting tools The first test of the head verification process starts with the endurance test unit. DANGER Da…

5 Working with the HCS
5.2 Head verification process
68 User Manual SIPLACE Head Care Station 10/2017
5.2.6.3 Starting the head verification
The Progress tab shows the previously selected measurements and the status of the individual
tests and the overall test sequence.
NOTICE
Previous settings still available
All previous settings are still available and can be changed any time before the head verific-
ation has been started.
► Click the Previous button to return to the previous page.
Fig.76: Progress tab
► Before you start the verification process, it is recommended to enable the Auto details op-
tion(2) so that the detailed test result is automatically displayed whenever new measurement
values are available.
► Click the Start button(3).
ð The head verification process is started.
ð The test status of the ongoing verification is displayed in the Status column for each test
from top to bottom. See 5.2.6.5 "Measurement progress" [}70].
ð When all tests are finished, the Summary tab is displayed.
CAUTION
Loss of verification data
Clicking the Cancel button(4) aborts the whole test and looses all previous settings. The
verification process then needs to be started from the beginning.
► Only click Cancel if you are sure to discard all results.

5 Working with the HCS
5.2 Head verification process
User Manual SIPLACE Head Care Station 10/2017 69
5.2.6.4 Inserting tools
The first test of the head verification process starts with the endurance test unit.
DANGER
Danger of crushing!
► Do not reach in the area between the tool and the z-axis.
► Insert the endurance test unit(3) in the tool
area.
► Make sure that the tool is correctly aligned
to the stopper(1) and the end stop with
sensors(2).
► Clamp the tool by means of the tool clamp-
ing piece(4).
► When the tool is inserted, close the door and press the Start button on top of the HCS.
ð The door is now locked and the verification process can be continued.
See also
2 3.1.1.1 "Tool area" [}35]

5 Working with the HCS
5.2 Head verification process
70 User Manual SIPLACE Head Care Station 10/2017
5.2.6.5 Measurement progress
After starting the head verification process, the software runs all measurements consecutively. The
process is only interrupted if a software error occurs or whenever a user interaction is required, for
example, to change tools.
The measurements are performed from top to bottom as shown in the Measurement step column
on the Progress tab:
Fig.77: Measurement progress
The status of each measurement is displayed in the Status column(1):
●
A gear wheel indicates that the measurement is in progress.
●
A green tick indicates that the measurement was successful.
●
A red cross indicates that the measurement failed.
► To selectively display test details of a running or already finished test(1), deactivate the Auto
Details(4) option, select a measurement and click the Details...(4) button.
► Use the arrow keys(2) on the left to navigate through the test details.
► Use the red arrow keys(3) on the right to navigate through tests which failed during the meas-
urements.
► Click the Stop button(5) to interrupt the current measurement and to unlock the door.
NOTICE
Stop aborts the current measurement
The measurement does not stop until it is finished. You can only restart the measurement
from the beginning, not from the point where it was interrupted.
► To restart the measurement, close the door and click Continue.
► Click the Cancel button(6) if you want to abort the whole verification.
CAUTION
Cancel aborts the whole verification
Clicking the Cancel button aborts the whole test and looses all previous settings. The veri-
fication process then needs to be started from the beginning.
► Only click Cancel if you are sure to discard all results.