5 Working with the HCS
5.4 Helpful HCS functions
72 User Manual SIPLACE Head Care Station 10/2017
5.4.2 Removing a user
To remove a user, select the Remove user function and proceed as described in 5.4.1 "Adding
users" [}71].
5.4.3 Setting up the test bench ID
Fig.79: Test bench machine ID function
Click the Test bench service icon(4).
From the list, select Test bench configura-
tion(1).
Select the Test bench machine ID function(2).
Click the Start button(3).
Enter the HCS ID written on the type plate or on
the label below the pneumatic unit and click OK.
Click the Test bench inspection icon(1) to re-
turn to the Meta data tab.
5.4.4 Checking / modifying the zero point correction
The individual measurements of a head verification process are performed using the data that is
stored in the SIPLACEmachine configuration. In some cases, the data readout from the machine
does not match the machine data of the HCS. Therefore, it is recommended to check / modify the
data before running the head verification.
Fig.80: Check sensors and functions
Click the Check sensors and functions icon(1).
Click the Check sensors and functions of spe-
cific components icon(2).
Open the head functions for the installed
head(3), for example, the CPP head.
5 Working with the HCS
5.4 Helpful HCS functions
User Manual SIPLACE Head Care Station 10/2017 73
Checking the zero correction data of the z-axis
Fig.81: Zero correction data of z-axis of C&P heads
For C&P heads, proceed as follows:
Log on as machine service. 5.2.4 "Changing the
user role" [}64]
Click the Check sensors and functions of z-
axis icon(2).
Click the Zero correction data tab(1).
Compare the machine data(3) to the head
EPROM data(5).
If the head EPROM data(5) is to be used, click
the arrow(4) to overwrite the machine data(3) or
click Edit… and enter the zero correction data.
To save your settings, click the Write head and
machine data button(6).
Fig.82: Zero correction data of z-axis of P&P modules
For P&P modules, proceed as for C&P heads, but
note that the Check sensors and functions of z-axis
icon(1) is different.
Checking the zero correction data of the star axis
Fig.83: Zero correction data of star axis of C&P heads
Click the Check sensors and functions of star
axis icon(1).
Click the Zero correction data tab.
Compare the machine data(2) to the HCS
data(4).
If the head EPROM data(2) is to be used, click
the arrow(3) to overwrite the machine data or
click Edit… and enter the zero correction data.
To save your settings, click the Write head and
machine data button(5).
5 Working with the HCS
5.4 Helpful HCS functions
74 User Manual SIPLACE Head Care Station 10/2017