3OM-1208-011_w.pdf - 第111页

3-24 AIVEDT -ID (A02_06) Sequence Set one of the following options to specify the timing of PEC recognition implementation. It is recommended that "After Pick Up" should be set in normal cases. Note The compone…

100%1 / 345
3-23
AIVEDT-ID
(A02_05)
Beam
It can be determined which beam should be used for the global and
image PEC recognition operations.
Stage 1
Beam 1 :
Select this when only Beam 1 should be used
for PEC recognition operations.
Beam 2 :
Select this when only Beam 2 should be used
for PEC recognition operations.
Automatic (1 or 2) :
The machine determines which beam (Beam
1 or 2) is more suitable for PEC recognition
operations and selects the better one.
Both Beam
:
Select this when both beams (Beams 1
and 2) should be used for PEC recognition
operations.
Stage 2
Beam 3 :
Select this when only Beam 3 should be used
for PEC recognition operations.
Beam 4 :
Select this when only Beam 4 should be used
for PEC recognition operations.
Automatic (3 or 4) :
The machine determines which beam (Beam
3 or 4) is more suitable for PEC recognition
operations and selects the better one.
Both Beam
:
Select this when both beams (Beams 3
and 4) should be used for PEC recognition
operations.
Reference
As for the local PEC recognition, the PEC recognition operations are
performed with the beam by which components are placed regardless of
this designation of the PEC recognition beams.
0606-009
1.2 Operation Data
3-24
AIVEDT-ID
(A02_06)
Sequence
Set one of the following options to specify the timing of PEC
recognition implementation.
It is recommended that "After Pick Up" should be set in normal cases.
Note
The components must meet the following requirements.
When "After Pick Up" is selected, a component is picked up and the
component recognition is performed on the component while the PCB is
being transferred to the PCB positioning section.
Since the component is already picked up, it can be placed soon after the
PEC recognition operation is performed, shortening the time to finish a
PCB.
Stage 1 and Stage 2
After Pick Up :
The PEC recognition operation is performed after a
component is picked up.
Before Pick Up :
The PEC recognition operation is performed before
a component is picked up.
This parameter should be selected when the PEC
recognition operation cannot be performed with a
component being picked up.
0606-009
1.2 Operation Data
3-25
AIVEDT-ID
1.2.3 (A03) PEC Recognition Mark Data
(A03_01)
Mark No.
The mark Nos. correspond to the mark codes and the specified
parameters of each fiducial mark used in the PEC recognition function.
10 types of mark codes can be registered for each pattern program.
(A03_02)
Mark
Type
The following options can be selected as shapes of fiducial marks.
Table 3C1-1
Mark Type Shape
Round
Square
Equilateral Triangle (Up)
Cross
Rectangle
Checker (Square)
Diamond
Equilateral Triangle (Down)
Bow Tie
Checker (Rectangle)
Table 3C1-2
Mark Type Shape Mark Type Shape
Through Hole
Pad Mark
Through Hole (E) Pad Mark (E)
Through Hole (SE) Pad Mark (SE)
Through Hole (S) Pad Mark (S)
Through Hole (SW) Pad Mark (SW)
Through Hole (W) Pad Mark (W)
Through Hole (NW) Pad Mark (NW)
Through Hole (N) Pad Mark (N)
Through Hole (NE) Pad Mark (NE)
0606-009
1.2 Operation Data