3OM-1208-011_w.pdf - 第123页
3-36 AIVEDT -ID (C01_03) C Set control commands in the text boxes. Notice If a control command other than the following ones is used, the step becomes invalid. - (hyphen) : This command handles the steps as those for the…

3-35
AIVEDT-ID
(C01_01)
Fdr No.
Shown are the feeder Nos. in the placement feeder location data.
The numbers in ( ) indicate the feeder Nos. that will actually be loaded
with components.
Feeder Base #1 :
101 to 150
Feeder Base #2 :
201 to 250
Feeder Base #3
:
301 to 350
Feeder Base #4 :
401 to 450
Work Area :
001 to 099
101 to 150 301 to 350
201 to 250 401 to 450
Front Side of Machine
Rear Side of Machine
Feeder Base #1
Feeder Base #2
Feeder Base #3
Feeder Base #4
Fig. 3C27
(C01_02)
Component ID
Set component IDs in the text boxes.
0606-009
1.4 Placement Feeder Location Data

3-36
AIVEDT-ID
(C01_03)
C
Set control commands in the text boxes.
Notice
If a control command other than the following ones is used, the step
becomes invalid.
- (hyphen) :
This command handles the steps as those for the
placement feeder location data.
E :
This command shows the end of the placement
feeder location data.
The step where "E" is set is valid.
S
:
This command invalidates the steps specified as
placement feeder location data.
X :
This command invalidates the steps specified as
placement feeder location data and shows the end
of the data.
(C01_04)
Comment
Set a comment for each Fdr No.
Up to 32 characters (alphanumerics and symbols) can be used.
Alphanumeric characters and symbols can be used.
Note
(a) The performance of the machine is not affected by these commands.
In other words, it has nothing to do with or without these comments.
(b) It is recommended to set helpful information on components related
to the feeder Nos. (Fdr No.).
(C01_05)
Feeder Fixed
Select "Enable" or "Disable" to determine whether or not the feeder
positions should be fixed in place.
When "Enable" is selected, the feeder Nos. (Fdr No.) and the
component ID are not affected by any insert and delete operations of a
component.
Disable :
The feeder position is not fixed.
Enable :
The feeder position is fixed.
0606-009
1.4 Placement Feeder Location Data

3-37
AIVEDT-ID
(C01_06)
Feeder Alternate
Select "Enable" or "Disable" to determine whether or not the feeder
alternate function should be used.
Disable :
The feeder alternate function is not used.
Enable :
The feeder alternate function is used.
(C01_07)
Fdr No.
When "Enable" is selected for the feeder alternate function, set the
destination feeder No. (Fdr No.) of the feeder that will work in place of
the feeder where a component pickup error has occurred in succession.
(C01_08)
Component Library Comment
Shown are the comments that were entered in the component library
data.
(C01_09)
Dir [deg], Carrier Data
Type, and Width [mm]
Shown are the values specified in the component library data.
(C01_10)
Fd. Pitch [mm]
Shown are the feed pitches specified in the component library data.
(C01_1
1)
Used Parts
Shown is the number of components to be used for one unit PCB.
0606-009
1.4 Placement Feeder Location Data