3OM-1208-011_w.pdf - 第153页
3-66 AIVEDT -ID • Placement Coordinates, Angles, and Fiducial Mark Coordinates X 3 Y 3 X 2 Y 2 X 1 FX 1 Y 1 FY 1 FY 2 FX 2 Placement Coordinate Reference Fiducial Mark Fiducial Mark Fig. 3C53 • List of Required Data T ab…

3-65
AIVEDT-ID
3.1 Single Pattern (Global Recognition Enabled)
(1) Information on Pattern Program Creation
•
PCB size
250 mm
1.6 mm
330 mm
PCB
PCB Flow Direction
Fig. 3C50
•
Packaged Posture and IDs of Components
[3]
[2]
[1]
User Direction of Feed
No. Component IDs
[1] TANA3216C0HIT
[2] TR2012-3B0HIT-L2
[3] S0P008-B02SAN32E
Fig. 3C51
•
Fiducial Mark
1.0 mm
Fig. 3C52
0606-009
3.1 Single Pattern (Global Recognition Enabled)

3-66
AIVEDT-ID
•
Placement Coordinates, Angles, and Fiducial Mark Coordinates
X3
Y3
X2
Y2
X1
FX1
Y1
FY1
FY2
FX2
Placement Coordinate
Reference
Fiducial Mark
Fiducial Mark
Fig. 3C53
•
List of Required Data
Table 3C4
Pattern Program Required Data
Operation Data PCB Data
PEC Recognition Data
PEC Recognition Mark Data
Setup Data Note (a)
Placement
Head/Nozzle Data
Heads 1 through 4
Placement Feeder
Location Data
Feeder Bases #1 through #4
Placement Data U01 P-data P-data
Unit Control Note (b)
Unit PCB Fiducial ×
O-data
×
Placement Data Un P-data P-data ×
Unit Control ×
Unit PCB Fiducial ×
O-data ×
Note
(a) Create this data for automatic conveyor width adjustment.
(b) Specify these parameters (data) according to the situational changes.
0606-009
3.1 Single Pattern (Global Recognition Enabled)

3-67
AIVEDT-ID
(2) Creation of Operation Data
•
PCB Data
T
able 3C5
PCB size X (Horizontal) [mm] 330.000
Y(Vertical) [mm] 250.000
T(Thickness) [mm] 1.600
PCB X(Horizontal) [mm] +0.000
origin offset Y (Vertical) [mm] +0.000
Z (deg) [] +0.00
XY-Angle [deg] [] +0.00
X-Direction Same
Y-Direction
Z Angular Orientation
PCB height offset [mm] +0.000
Placement Reference
Front Right
PCB locate Sequence
Standard
PCB transfer Sequence
Output Priority
Pre-Placed component Top [mm] 0.000
thickness
Bottom [mm] 0.000
PCB transfer speed Input
Between Stages
Output
Input Conveyor Y Position arrange speed setup
(% deceleration)[%]
0
0
PCB locate mode Stage 1 Operation
Std
Stage 2 Operation
Std
Placement mode Stage 1
Placement
Stage 2 Pass
Recovery regulation U-N Stage 1
Disable
Stage 2
Block Sort
Same
Same
Standard
Standard
Standard
Output Conveyor Y Position arrange speed setup
(% deceleration)[%]
Stage 1
Stage 2
Disable
Disable
Disable
0606-009