6-63 AIVEDT -ID [4] Simultaneous transfer setup Set "Enable" or "Disable" to determine whether or not the PCB transfer should be made simultaneously between the input and positioning conveyors and bet…

100%1 / 345
6-62
AIVEDT-ID
[1] PCB transfer direction
Select one of the following options to determine the PCB transfer
direction.
L
R
:
The PCB flows from the left to the right.
R
L :
The PCB flows from the right to the left.
Note
When the setting is changed, it is required to perform the zeroing operation
again.
[2] Transfer Reference conveyor specify
Select one of the following options to determine the transfer reference
side for the PCB transfer.
Rear :
The rear side is specified as a transfer reference.
Front :
The front side is specifi
ed as a transfer reference.
[3] Auto stop mode
"Enable" or "Disable" can be set in this text box to determine whether
or not the automatic stop function should be used.
"Enable" in "Auto stop mode" Text Box (Standard Setting)
The machine stops when the automatic operation is started by pressing
the [START] button with the machine in the initialized mode (no PCB
on the machine, the machine is waiting for a PCB to be sent from the
input machine and detects that "RUN" signal has stopped coming
from the input machine, and the machine is kept in the condition for 2
seconds.
This function is based on the concept that it will be necessary to
continue automatic operation of the machine when there is no PCB on
the machine and the input
machi
ne is not running automatically because
it is apparent that no PCB can be transferred to the machine anymore.
The machine stops automatically when a PCB on the machine is
processed without unprocessed PCB left on the machine and the input
machine is stopped after the last processed PCB on the machine has
been transferred to the output machine.
Note
When the machine is connected to another machine manufactured by
another company, this function may not be activated.
2.2 Auto Operation
0606-009
6-63
AIVEDT-ID
[4] Simultaneous transfer setup
Set "Enable" or "Disable" to determine whether or not the PCB transfer
should be made simultaneously between the input and positioning
conveyors and between the positioning and output conveyors.
[5] Output conveyor PCB Out
Set "Disable" or "Enable" to determine whether or not a disengaged
PCB should be detected in the output conveyor section.
[6] Furnace Signal Check
Set "Disable" or Enable" to determine whether or not the furnace signal
check function should be activated.
Note
When "SMEMA" is set in the "Input mode" text box of the label "Input
Setup" or in the "Output mode" text box of the label "Output Setup", this
function cannot be used.
2.2 Auto Operation
0606-009
6-64
AIVEDT-ID
[7] Input Setup
Input mode
Select a parameter according to the PCB unloading system of the input
machine.
Conveyor
The input machine is activated to receive a PCB from the input
machine when the PCB transfer signal is received from the input
machine.
Pusher
The pusher of the input machine forces a PCB out to the input
conveyor of the machine.
When the PCB detection sensor (for the pusher) is not provided at
the inlet side of the input conveyor
, do not set "Pusher" in the text
box.
SMEMA
PCBs are transferred according to the "SMEMA" standard.
Pusher delay timer [sec]
When "Pusher" is set in the "Input mode" text box of the label "Input
Setup", it is required to specify the delay (waiting) time for the loading
action to start after the inlet sensor has detected a PCB.
PCB delivery Position
Set the position where PCBs are received.
T
ransfer speed
Set the PCB transfer speed.
Default:
300 [mm/sec]
2.2 Auto Operation
0606-009