3OM-1208-011_w.pdf - 第300页

6-67 AIVEDT -ID 0606-009 2.3 Configuration Setup Data 2.3.1 Light T ower Setup The corresponding tab sheet enables the operator to allocate the lamp colors for the light tower and the buzzer sounds. When the "Light T…

100%1 / 345
6-66
AIVEDT-ID
[9] Input conveyor
Timer #1 [sec]
Set the time to limit the operating time (PCB reception from the input
machine) of the input conveyor
.
This timer measures the operating time of the input conveyor and is
used to detect an interrupted PCB.
Add 2 seconds (approx.) to the time required for PCB reception from
the input machine and set the time in the text box.
Note
Add 2 seconds (approx.) to the time required for PCB reception from the input
machine and set the time in the text box.
[10] PCB locate
Stopper setup
"Enable" or "Disable" can be selected to determine whether or not the
PCB positioning stopper should be used for the PCB positioning.
"Enable"
:
The PCB positioning stopper is used.
"Disable" :
The PCB positioning stopper is not used.
[1
1] Output conveyor
Timer #1 [sec]
Set the time to limit the operating time (PCB reception by the output
machine) of the output conveyor.
Note
Add 2 seconds (approx.) to the time required for PCB reception by the output
machine and set the time in the text box.
2.2 Auto Operation
0606-009
6-67
AIVEDT-ID
0606-009
2.3 Configuration Setup Data
2.3.1 Light Tower Setup
The corresponding tab sheet enables the operator to allocate the lamp colors
for the light tower and the buzzer sounds.
When the "Light Tower Setup" tab is pressed in the "Configuration Setup"
tab sheet, the following tab sheet appears.
[4]
[2] [3]
[1]
Fig. 3F57 "Light Tower Setup" Tab Sheet
[1] Data Name
Displayed are the items for which the colors (red, yellow, and green) of
the tower lights and the types of alarm sounds should be specified.
[2] Red, Yellow, Green
Set "ON", "ON AND OFF", or "OFF" for the tower lights (red, yellow,
and green).
[3]
Buzzer
Set "Off", "Intmt Snd", "Cont Snd", or "Optl Snd" in each text box to
specify the types of alarm sounds.
The desired sound patterns can be made, using the "Alarm Setup" tab
sheet.
Note
When the icon ( ) is pressed, the standard settings (defaults) resume.
2.3 Configuration Setup Data
6-68
AIVEDT-ID
[4] Tower Light ON/OFF Selection Buttons
[Display Pattern #1], [Display Pattern #2], and [Display Pattern
#3] Buttons
These buttons can be used to change the setting of each tower light.
When one of these buttons is selected, the corresponding lighting
pattern appears, enabling you to change the settings.
0606-009
2.3 Configuration Setup Data