Retrofit instructions Splice Detection Basic Package + Tab le Controller SIPLACE HF-series 08/2005 Edition 34 : Plug the connectors into the communica tion interfac e (see picture below). 2 : Run the six cables (as shown…

Retrofit instructions Splice Detection Basic Package + Table Controller SIPLACE HF-series
08/2005 Edition
33
2.9 Installing the basic package and connecting the
communication interface
2
: Use four screws to screw the communication interface to the machine base.
The screw holes are predrilled (see photo below).
: Screw the ground connection with a Phillips screw.
2
Assembly position for
the communication
interface
Ground
Screw
Screw

Retrofit instructions Splice Detection Basic Package + Table Controller SIPLACE HF-series
08/2005 Edition
34
: Plug the connectors into the communication interface (see picture below).
2
: Run the six cables (as shown in the picture above) into the opening in the machine base.
: Run the power supply cable.
2
Power supply
connection
Table
1 2 3 4
Connecting cables
CAT5 cables)
to component trolley 1-4
Connecting cable
to 03007804

Retrofit instructions Splice Detection Basic Package + Table Controller SIPLACE HF-series
08/2005 Edition
35
: Secure the cables with cable ties.
: Connect the power supply cable to the terminals shown in the picture.
2
At the clamping fields of newer machines possibly only one connection is free.
Measure the connection before connecting the cable to avoid damage caused by false voltage!2
2
White = GND
Brown = +15V
Position of the terminals