0900766b8171bf63.pdf - 第8页

8 MY(S) Detailed Information on Mod els Certified for Safety St andards, MY2(S)/MY4(S)/MY4Z(S) VDE-certified Models (No. 112467UG, EN61810-1) UL508-certified Models (File No. 41515) CSA 22.2 No. 14-certified Models (File…

100%1 / 36
MY(S)
7
Engineering Data MY(S) (MY2ZN, MY@F)
Ambient Temperature vs.
Must-operate and Must-release Voltage
Ambient Temperature vs. Coil Temperature Rise
MY2 AC Models MY2 AC Models, 50 Hz MY2 DC Models
MY2 DC Models MY4 AC Models, 50 Hz MY4 DC Models
MY4 AC Models
MY4 DC Models
Models with built-in diodes
The diode absorbs surge from the coil. This type is best suited for applications with semiconductor circuits.
With Diode
Without Diode
Note: 1. Make sure that the polarity is correct.
2. The release time will increase, but the 20-ms specification for standard models is satisfied.
3. Diode properties:The diode has a reversed dielectric strength of 1,000 V.
Forward current: 1 A
Models with Built-in CR Circuits
With CR Without CR
100
80
60
40
20
0
60 30 0 30 60 90
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
120
100
110
80
90
70
60
50
40
10
20
30
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
Temperature rise (°C)
When rated voltage is applied
5 A contact current × 2 circuits
2.5 A contact current × 2 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
120
100
110
80
90
70
60
50
40
10
20
30
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
Temperature rise (°C)
When rated voltage is applied
5 A contact current × 2 circuits
2.5 A contact current × 2 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
60 30 0 30 60 90
100
80
60
40
20
0
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
10 20 30 40 50 60 70 80
Ambient temperature (°C)
When rated voltage is applied
3 A contact current × 4 circuits
1.5 A contact current × 4 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
120
100
110
80
90
70
60
50
40
10
20
30
0
Temperature rise (°C)
120
100
110
80
90
70
60
50
40
10
20
30
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
Temperature rise (°C)
When rated voltage is applied
3 A contact current × 4 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
1.5 A contact current × 4 circuits
60 30 0 30 60 90
80
60
40
20
0
100
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
60 30 0 30 60 90
100
80
60
40
20
0
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
OFFON
A
A’
Di
To digital
memory
24 VDC
OFFON
A
A’
To digital
memory
24 VDC
140 V
A
A’
C = 0.033 μF
R = 6.8 kΩ
282 V
80 V
4.12 ms
9.4 ms
200 AC
A
A’
A
A’
To digital
memory
scope
msec
2.5
600 V
282 V
ms
2.5
200 AC
8
MY(S)
Detailed Information on Models Certified for Safety Standards, MY2(S)/MY4(S)/MY4Z(S)
VDE-certified Models (No. 112467UG, EN61810-1)
UL508-certified Models (File No. 41515)
CSA 22.2 No. 14-certified Models (File No. LR31928)
LR-certified Models (File No. 98/10014)
Model Coil ratings Contact form Contact ratings File No. Certified number of operations
MY@
6, 12, 24, 48/50, 100/
110, 110/120, 200/
220, and 220/240 VAC
6, 12, 24, 48, 100/
110, and 125 VDC
DPDT
10 A, 250 VAC (cos φ = 1)
10 A, 30 VDC (L/R = 0 ms)
6692 (VDE0435)
MY2: 10,000 operations
MY4: 100,000 operations
MY4Z: 50,000 operations (AC)
4PDT
5 A, 250 VAC (cos φ = 1)
5 A, 30 VDC (L/R = 0 ms)
Model Coil ratings Contact form Contact ratings File No. Certified number of operations
MY@
6 to 240 VAC
6 to 125 VDC
DPDT
10A, 250 VAC (General Use)
E41515 (UL508)
6,000
10A, 30 VDC (General Use)
7A, 240 VAC (General Use)
7A, 24 VDC (Resistive)
5A, 240 VAC (General Use)
5A, 250 VAC (Resistive)
5A, 30 VDC (Resistive)
3A, 265 VAC (Resistive)
1/6HP, 250 VAC
1,0001/8HP, 265 VAC
1/10HP, 120 VAC
B300 Pilot Duty (Same polarity) 6,000
4PDT
5A, 28 VDC (General Use) (Same polarity)
6,000
5A, 240 VAC (General Use) (Same polarity)
5A, 30 VDC (Resistive) (Same polarity)
5A, 250 VAC (Resistive) (Same polarity)
0.2A, 120 VDC (Resistive) (Same polarity)
1/6HP, 250 VAC (Same polarity)
1,000
1/10HP, 120 VAC (Same polarity)
B300 Pilot Duty (Same polarity) 6,000
Model Coil ratings Contact form Contact ratings File No. Certified number of operations
MY@
6 to 240 VAC
6 to 125 VDC
DPDT
7A, 240 VAC (General Use)
LR31928
(CSA C22.2)
(No. 14)
6,000
7A, 24 VDC (Resistive)
5A, 240 VAC (General Use)
5A, 250 VAC (Resistive)
5A, 30 VDC (Resistive)
3A, 265 VAC (Resistive)
1/6HP, 250 VAC
1,0001/8HP, 265 VAC
1/10HP, 120 VAC
B300 Pilot Duty (Same polarity) 6,000
4PDT
5A, 240 VAC (General Use) (Same polarity)
6,000
5A, 28 VDC (General Use) (Same polarity)
5A, 250 VAC (Resistive) (Same polarity)
5A, 30 VDC (Resistive) (Same polarity)
0.2A, 120 VDC (Resistive) (Same polarity)
1/6HP, 250 VAC (Same polarity)
1,000
1/10HP, 120 VAC (Same polarity)
B300 Pilot Duty (Same polarity) 6,000
Model Coil ratings Contact form Contact ratings File No. Certified number of operations
MY@
6 to 240 VAC
6 to 125 VDC
DPDT
10 A, 250 VAC (resistive)
2 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
2 A, 30 VDC (L/R = 7 ms)
98/10014
MY2: 50,000 operations
MY4: 50,000 operations
4PDT
5 A, 250 VAC (resistive)
0.8 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
1.5 A, 30 VDC (L/R = 7 ms)
MY(S)
9
Miniature Power Relays: MY2ZN
Specifications
Contact Ratings
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.
Characteristics
Refer to the standards certifications and compliance
section of your OMRON website for the latest
information on certified models.
Load
Item
Resistive load
Inductive load
(cos φ = 0.4, L/R = 7 ms)
Rated load
5 A at 220 VAC
5 A at 24 VDC
2 A at 220 VAC
2 A at 24 VDC
Rated carry current 5 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5 A
Contact form DPDT (Bifurcated)
Contact materials Au plating + Ag
Type
Item
Standard
models
Model with built-in operation
indicator, diode, or CR circuit
Ambient
operating
temperature
*1
55 to 70° C 55 to 60° C
*2
Ambient
operating
humidity
5% to 85%
Item MY2ZN series
Contact resistance
*1
50 mΩ max.
Operation time
*2
20 ms max.
Release time
*2
20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance
*3
100 MΩ min.
Dielectric
strength
Between coil and contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of the
same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 200 m/s
2
Endurance
Mechanical 50,000,000 operations min. (operating frequency: 18,000 operations/h)
Electrical
*4
200,000 operations min. (rated load, switching frequency: 1,800 operations/h)
Item MY2ZN Note: These are initial values.
Failure rate P value
(reference value)
*5
100 μA at 1 VDC
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method.
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23°C
*5. This value was measured at a switching frequency of 120 operations per minute.
Weight Approx. 35 g