TR7500E_Manual_en_v28 - 第242页
C h a p t e r 4 T r a i n d i a l og f u n c t i on T R 7500 U S E R M A N U AL 2 35 ( 1 8) C h a n g e S h a p e – T h e f u n c ti o n i s t o c h a n g e t h e w i n d o w s h a p e fr o m s qu a r e t o c i r c l e o…

Chapter 4 Train dialog function
TR7500 USER MANUAL
234
(10) Move to Left FOV – Move the selected box to the left FOV.
(11) Move to Right FOV –Move the selected box to the right FOV..
(12) Rotate Box Side – Rotate the pin direction with 90 degrees of
counterclockwise for clicking once.
(13) Set Logic – Set the Logic between windows. See more about logic in
Chapter 3 10.7.1. .
(14) Inverse Logic – Checks this item to start the [Inverse Logic] function. After
you select this function, the system regards a box that is passing the pass
level as failed and a box that is not passing the pass level as passed.
(15) Test – Set the selected inspection box as [Test Box] or [Test component].
It establishes it with [untest] correspond to
(16) Untest –Set the selected inspection box as [UnTest Box] or [UnTest
component]. [UnTest Box] means only set the selected box as untested and
the box become blue; [UnTest Component] means set the all boxes in
selected component as untested and the boxes become gray.
(17) Set to Library – Sent the information of [Pass Level] or [Search Range] of
the selected box to Library. You can only select the inspection boxes that is
belonging to a component. And [Weighting] is only for TR7500E series.

Chapter 4 Train dialog function
TR7500 USER MANUAL
235
(18) Change Shape – The function is to change the window shape from square to
circle or from circle to square. It only works for [Void] or [Solder] window.
5.2. The boxes in FOV image
l Purple – Multi-function window. You can select a [Missing/Missing Polarity] or
[Lead] box and double click on the multi-function window. The multi-function
window will be moved to the selected window.
l Orange – Untrained box.
l Dark blue – Untested inspection window.
l Gray – Untested component.
l Red – Selected box. You can double click one box and the system will selected
the all inspection boxes that are linked with selected box automatically.
l Light blue – The inspection boxes in other FOVs.
l Light purple – [Missing/Missing Polarity] or [Lead]
l Light green – Inspection boxes except [Missing/Missing Polarity/Lead].
6. Function Area
6.1. Function Frame
l You can click the train dialog then press [F1] to change the characters of button
to hot keys. Press once again and switch over.

Chapter 4 Train dialog function
TR7500 USER MANUAL
236