TR7500E_Manual_en_v28 - 第242页

C h a p t e r 4 T r a i n d i a l og f u n c t i on T R 7500 U S E R M A N U AL 2 35 ( 1 8) C h a n g e S h a p e – T h e f u n c ti o n i s t o c h a n g e t h e w i n d o w s h a p e fr o m s qu a r e t o c i r c l e o…

100%1 / 292
Chapter 4 Train dialog function
TR7500 USER MANUAL
234
(10) Move to Left FOV Move the selected box to the left FOV.
(11) Move to Right FOV Move the selected box to the right FOV..
(12) Rotate Box Side Rotate the pin direction with 90 degrees of
counterclockwise for clicking once.
(13) Set Logic Set the Logic between windows. See more about logic in
Chapter 3 10.7.1. .
(14) Inverse Logic Checks this item to start the [Inverse Logic] function. After
you select this function, the system regards a box that is passing the pass
level as failed and a box that is not passing the pass level as passed.
(15) Test Set the selected inspection box as [Test Box] or [Test component].
It establishes it with [untest] correspond to
(16) Untest Set the selected inspection box as [UnTest Box] or [UnTest
component]. [UnTest Box] means only set the selected box as untested and
the box become blue; [UnTest Component] means set the all boxes in
selected component as untested and the boxes become gray.
(17) Set to Library Sent the information of [Pass Level] or [Search Range] of
the selected box to Library. You can only select the inspection boxes that is
belonging to a component. And [Weighting] is only for TR7500E series.
Chapter 4 Train dialog function
TR7500 USER MANUAL
235
(18) Change Shape The function is to change the window shape from square to
circle or from circle to square. It only works for [Void] or [Solder] window.
5.2. The boxes in FOV image
l Purple Multi-function window. You can select a [Missing/Missing Polarity] or
[Lead] box and double click on the multi-function window. The multi-function
window will be moved to the selected window.
l Orange Untrained box.
l Dark blue Untested inspection window.
l Gray Untested component.
l Red Selected box. You can double click one box and the system will selected
the all inspection boxes that are linked with selected box automatically.
l Light blue The inspection boxes in other FOVs.
l Light purple [Missing/Missing Polarity] or [Lead]
l Light green Inspection boxes except [Missing/Missing Polarity/Lead].
6. Function Area
6.1. Function Frame
l You can click the train dialog then press [F1] to change the characters of button
to hot keys. Press once again and switch over.
Chapter 4 Train dialog function
TR7500 USER MANUAL
236