00195193-02 SG D4 FSE en (1) - 第121页
Reference run Reference Run C&P12 Height reference run S tudent Guide SIPLACE D4 (FSE) Reference run EN 09/2006 11 4 5.3.1 1 Height reference run With this function, we check whether the fitting on th e sleeve is cor…

Reference run
Measuring Nozzle Lengths for Component Recognition by the Component Sensor Reference Run C&P12
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Reference run
113
Legend
1. The vacuum is measured twice at the reference point: once with closed and once with open valve,
while air flows through the nozzle.
2. The value with closed valve depends on the ambient pressure and may vary significantly, according
to the local weather conditions and altitude. The higher the ambient pressure, the lower the vacuum
at closed valve.
3. The value by open valve depends on the nozzle size and condition. The smaller the nozzle, the
greater the open valve value will be. A contaminated or blocked nozzle will also give a higher valve.
4. The difference between the open and closed nozzles has been preset by the line computer as an
ideal case minimum value. This value is different for all nozzle types e.g. 120 mbar for 714, 704, 914
and 904 nozzles. If these values are not achieved, the error message "Vakuumdifferenz offen-
geschlossen zu gering" (vacuum difference open-closed is too low) will appear.
5. The threshold for component acceptance is also set now. In this case we have a value of 700 mbar
when the nozzle is open and a value of 900 mbar when the nozzle is closed. The calculation is
performed as follows:
Threshold = (900(closed) - 700(open))= x 0.2 + 700(open) = 200 x 0.2 + 700 = 740
5.3.10 Measuring Nozzle Lengths for Component Recognition by the Component
Sensor
The component sensor option can only be used with machine stations SW 503 or higher and only with
12 nozzle C&P placement heads.
If the CO sensor option is installed on the C&P12, the following will be performed during the vacuum
reference run:
The length of the nozzle in the IR beam will be measured during star revolution.
The SIPLACE Pro/LC defines which nozzle type can be measured (nozzle lengths longer than
12 mm). Nozzle setup on the placement star triggers measurement.
Before pickup, the length of the empty nozzle is compared to the value measured during the
reference run.
During the placement process, component recognition refers to the empty nozzle measurement
value before placement is performed.
Legend:
1. IR receiver
2. Nozzle
3. IR transmitter

Reference run
Reference Run C&P12 Height reference run
Student Guide SIPLACE D4 (FSE)
Reference run EN 09/2006
114
5.3.11 Height reference run
With this function, we check whether the fitting on the sleeve is correct and whether the correct nozzle
type (set by the placement program) is programmed. The nozzle length is taken to calculate the pick up
and placement height for the following placements. This height reference run is not dependent on the
nozzle length measurement in the CO sensor!
Legend:
1. Top of the fixed conveyor side
2. First step with segment 1 for measure the
nozzle height.
3. Last step with segment 6 (12) for measure the
nozzle height.
The gantry moves the placement heads above
the fixed conveyor side.
The Z- axis runs down, and all nozzles touch
the transport rail.
Nozzle 1 defines the reference length.
All segments are measured according to there
specific length reffering to nozzle 1.
The maximum length tolerance is 0,4 mm: If
the length difference is too high an error
message is displayed.
NOTE: Exception:
special nozzle with type number X9X are only measured (there is no length
specification).

Services to the machine
Overview
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Services to the machine
115
6 Services to the machine
6.1 Overview
The diagram below shows where the energy supplying and distributing components for system operation
are installed:
6.1 - 1: Main components in SIPLACE D4
Legend:
1 Sector distributor for sector 1 5 Transport direction
2 Sector distributor for sector 2 6 Pneumatic unit
3 Sector distributor for sector 3 7 Power Supply Unit
4 Sector distributor for sector 4