C&P12 Placement Head Compressed Air Supp ly - C&P Head Overview Student Guide SIPLACE D4 (FSE) EN 09/2006 C&P12 Placement Head 191 9.1.5 Compressed Ai r Supply - C&P Head 9.1.5.1 V acuum generator The pla…

C&P12 Placement Head
Overview Overview parts on the C&P12 Head
Student Guide SIPLACE D4 (FSE)
C&P12 Placement Head EN 09/2006
190
Legend - Overview of Parts 2
1. Air kiss unit / DLM2
(Article no. 00367793-01)
2. Silencer
(Article no. 03003134-01)
3. Turning station / DLM2
(Article no. 00341780-03)
4. CO camera 18x18
(Article no. 03014449-02)
CO camera 27 x 27
(Article no. 03018637-01)
Legend - Overview of Parts 3
1. Star fitted / DLM2
2. "Z-axis down" sensor
3. RSF digital encoder 12/DLM2

C&P12 Placement Head
Compressed Air Supply - C&P Head Overview
Student Guide SIPLACE D4 (FSE)
EN 09/2006 C&P12 Placement Head
191
9.1.5 Compressed Air Supply - C&P Head
9.1.5.1 Vacuum generator
The placement head is supplied with 4.5 bar
compressed air from the pneumatic unit. The 7-
fold pneumatic hose is also used to cool the Y-axis
motor.
Legend:
1. Input: Discharged air Venturi nozzle
pneumatic hose (PK12)
2. Input: 7-fold pneumatic hose (PK 5)
3. Silencer for discharged air
4. Compressed air for the pickup / placement
circuit (PK6)
5. Compressed air for hold circuit (PK8)
Legend:
1. Hold circuit
2. Placement and pickup circuit for air kiss
3. Vacuum measuring board
4. Discharged air from the vacuum system to the
silencer compressed air distributor

C&P12 Placement Head
Overview Overview air kiss supply
Student Guide SIPLACE D4 (FSE)
C&P12 Placement Head EN 09/2006
192
9.1.6 Overview air kiss supply
9.1 - 1: General overview of the function Air kiss