00195193-02 SG D4 FSE en (1) - 第242页

C&P12 Placement Head Determining the Zero Point Corr ection for the Star Axis of the C&P Head Settings Student Guide SIPLACE D4 (FSE) EN 09/2006 C&P12 Placement Head 227 9.5.8 Determining the Zero Poi nt Corr…

100%1 / 340
C&P12 Placement Head
Settings Light Barrier, Bottom Position
Student Guide SIPLACE D4 (FSE)
C&P12 Placement Head EN 09/2006
226
X Loosen the Z-axis end position stop screw.
X Clamp a 15/100 mm feeler gauge between the Z limit stop and the clamp. Gently press the Z-axis
end position stop downwards with the screwdriver and screw tight.
X It should now be more difficult to extract the 15/100 mm feeler gauge.
X Check again whether the 5/100 mm feeler gauge passes easily (without resistance) between the Z-
axis end position stop and the tension jack. If this is not the case, you will need to readjust the setting!
9.5.7 Light Barrier, Bottom Position
Legend:
1. Z-Limit stop
2. feeler gauge
3. Clamping device
NOTE:
When removing the gauge, make sure that the gauge pin is extracted first and
that then the star gauge is removed. If you do not observe this order, the gauge
could catch in the segments and damage these!
NOTE:
The light barrier is set with a test probe to a distance of 1.0 mm to the sleeve.
C&P12 Placement Head
Determining the Zero Point Correction for the Star Axis of the C&P Head Settings
Student Guide SIPLACE D4 (FSE)
EN 09/2006 C&P12 Placement Head
227
9.5.8 Determining the Zero Point Correction for the Star Axis of the C&P Head
During this process, make sure you adhere exactly
to the specified order and observe the comments
to each step!
C&P12 Placement Head
Settings Adjustment of Mechanical Position of Valve Drives
Student Guide SIPLACE D4 (FSE)
C&P12 Placement Head EN 09/2006
228
9.5.9 Adjustment of Mechanical Position of Valve Drives
9.5.10 Air Pressure Values
9.5.10.1 Tools and Devices
A set of slotted screw drivers
Compressed air testing device
X Set the motor position of the valve positioning
drives "pickup/placement" and "reject" as
shown in the diagram.
X If the new valve plungers are used (s. diag. on
left) proceed as follows:
Take out one valve plunger and remove the
plastic bushing (2).
Insert the plunger without bushing and carry
out the following steps on this segment:
X Insert the distance gauge (0.2 mm) between
valve plunger and valve casing.
X Rotate the valve positioning drive 90 degrees
from its initial position. The excentric of the
valve drive will just touch the inner flange of
the valve.
X Fix the motor of the valve drive in this position.
X Remember to replace the tube on the valve
plunger.