Component handling
Overview Technical Data component table:
Student Guide SIPLACE D4 (FSE)
Component handling EN 09/2006
234
10.1.1 Technical Data component table:
Feeder capacity 144 tracks width 8mm (3x8mm S feeder)
96 tracks width 8mm (2x8mm S feeder)
Location 4 Component tables with the integrated tape waste container
12 tracks with 30 mm for each CO changeover table
undocking Tapes, Bulkcase, Linear magazin, Siplace S-Feeder(F4,F5,S-20,S-
23,S25HM,S27HM,HS50,HS50+,HS60), OEM Feeder, Surftape feeder (8, 12,
16, 24 mm), manual Trays
Interface to the
machine
Plug-in connection to machine
- Power supply
- CAN bus connection
- Closing the safety loop
- Compressed air connection
- Splice point recognition connection (optional)
Component table
height
depend from the machine height:
830 mm ± 15 mm (standard)
900 mm ± 15 mm (SMEMA)
930 mm ± 15 mm (SMEMA)
950 mm ± 15 mm (SMEMA)
Component handling
CO Changeover Table Construction (S Table) Overview
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Component handling
235
10.1.2 CO Changeover Table Construction (S Table)
See also:
J 10.1 Overview [J 233]
Legend:
1. flexible base
2. Tape reels container
3. Handles
4. Tape waste container
5. Communication unit; Splice recognition unit
option is installed below the communication
unit
6. Feeder table plate
7. Switch for lowering the CO table
8. Slot for set up lists on both sides
9. Voltage 30 V communication unit (yellow LED)
Component handling
Overview Assembly
Student Guide SIPLACE D4 (FSE)
Component handling EN 09/2006
236
10.1.3 Assembly
The trolley is easily moved and maneuvered.
The handles can be swung up or down.
The CO table has a maximum capacity of 12 locations for feeder modules with widths of 30 mm. These
feeder modules are mechanically centered on the table with centering pins and spherical calottes. The
bulkcase feeders are supplied with compressed air from a separate line.
A cable provides the interface connection to the machine. The power supply, communication and
emergency stop circuits are run via this cable. The compressed air supply for the bulkcase feeder
modules is also covered by this interface.
The communication unit supplies the feeder modules with the required voltages and control signals.
The tape reel container accepts tape reels up to a size of 19" (483 mm). The extractable waste tape
container is located on the underside of the flexible base. These waste tape clippings are taken down a
chute, into the waste container (which requires regular emptying).
See also:
J 10.1 Overview [J 233]
ATTENTION: Operational Safety
To operate the machine, all CO trolleys must be docked onto the machine. If
this is not the case, the machine will remain in emergency stop mode and the
placement process will be interrupted.
CAUTION:
Unused locations need to be occupied by a dummy feeder, to prevent access
to the machine at those points (risk of injury from reaching into the machine).