Sitest Calibrate all heads and cameras Calibration Student Guide SIPLACE D4 (FSE) EN 09/2006 Sitest 291 12.2 - 3: Main menu for calibrating the entire machine X Select All heads and cameras... 12.2.5 Calibrate all heads …

100%1 / 340
Sitest
Calibration Operation for calibrating the entire machine
Student Guide SIPLACE D4 (FSE)
Sitest EN 09/2006
290
12.2.4 Operation for calibrating the entire machine
X Start SITEST
X Perform a complete reference run.
12.2 - 2: Calibrating the entire machine
X Select
Calibrate machine...
NOTE:
For preparation details, see Section 12.2.2 Precondition for Calibration of SI-
PLACE D [J 288].
Sitest
Calibrate all heads and cameras Calibration
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Sitest
291
12.2 - 3: Main menu for calibrating the entire machine
X Select
All heads and cameras...
12.2.5 Calibrate all heads and cameras
12.2 - 4: All heads and cameras (default settings)
NOTE:
If you want to calibrate only one placement area deactivate all points in the field
PAx Calibration and Gantries. For individual calibration steps for C&P heads,
see Section 12.2.5.2 C&P Head [J 292].
Sitest
Calibration Calibrate all heads and cameras
Student Guide SIPLACE D4 (FSE)
Sitest EN 09/2006
292
X Select all points which you must calibrate
X Select
Execute mode
(if using parallel execution, prepare both processing areas, calibration tools
and nozzles in advance).
X Select
Job confirmation mode
.
X Click on
Start
.
12.2.5.1 Job confirmation mode
Don't wait:When this function is activated, the next job is carried out immediately after a job is
completed or an error occurs, without waiting for confirmation.
Always wait:When this function is activated, the next job is not carried out until confirmation is
received after a job is completed or an error occurs. You must click the Next job button to do this.
Wait in case of error:When this function is activated, the job is interrupted if an error occurs and the
next job is not carried out until confirmation is received. You must click the Next job button to do this.