00195193-02 SG D4 FSE en (1) - 第324页

Sitest New function in the Sitest program Basic description of all calibration steps Student Guide SIPLACE D4 (FSE) EN 09/2006 Sitest 305 12.3.10 New function in the Sitest program 12.3.10.1 Menu of transport 12.3 - 6: T…

100%1 / 340
Sitest
Basic description of all calibration steps Head Mapping (C&P Head)
Student Guide SIPLACE D4 (FSE)
Sitest EN 09/2006
304
12.3 - 5: Result of PCB mapping
The results will be saved in the file
MAPP_xy.MA
(x= gantry number, y= conveyor lane).
12.3.9 Head Mapping (C&P Head)
Head mapping measures the linearity of the C&P head X/Y guidance.
The C&P head places the calibration tool precisely on the default positions of the mapping plate.The
PCB-camera measure the placement accuracy of this placements for the whole placement area.
After the PCB mapping the placement head place at the theoretical positions of the PCB-mapping
the calibration tool.
The PCB camera measures the placement accuracy with the help of the 4 calibration tool fiducials
on the calibration tool upper side.
NOTE:
All described automatically calibration steps above, can you do manually step
by step under the sub menus (see chapter 12.1).
Sitest
New function in the Sitest program Basic description of all calibration steps
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Sitest
305
12.3.10 New function in the Sitest program
12.3.10.1 Menu of transport
12.3 - 6: Transport - option and configuration
Legend
1.
Changing the conveyor width
(only for lane 1, if dual conveyor):
You will see a submenu, in which you can select
Widened
or
Not widened
(standard width).
Widened means that lane 2 is moved together (to the limit switch), while the fixed side for lane 1
remains in its position. (max. width of lane 1 = 380 mm)
If point 4 is selected first (excess width) this gives a max. width for lane 1 of 430 mm.
2.
Change transport mode
:
This function is used to configure the option
Long Board
.
Next menu:
normal PCB/ long PCB
3.
Show stop positions
:
shows the number of position in PA 1 and PA2, additional the offset depend on the standard position
(PCB Reference- corner). The offset for the option
Long Board
is set by SIPLACE Pro.
4. This enables you to move the fixed conveyor side in its standard position to accommodate standard
or excess width boards (values from the conveyor control machine data).
Excess width means that the fixed side is moved up to 26 mm. (dual conveyor lane 1 and lane 2 =
242 mm, flexible dual conveyor lane 1 = 430 mm, single conveyor = 508 mm)
5. Point 5 and 6 only with Siemens Service Passwort active! The fixed conveyor side (
left, right
) can
be taught.
6. Save the teach data from point 5.
Sitest
Basic description of all calibration steps New function in the Sitest program
Student Guide SIPLACE D4 (FSE)
Sitest EN 09/2006
306
12.3.10.2 Function Firmware download
X Select
Settings
from the SITEST menu and then
Firmware
Download
.
12.3 - 7: Overview of firmware download
12.3 - 8: Firmware download
In the Can FW folder there are all current Firmware versions of all axes, tables etc.