Sitest Basic description of all calibration steps New function in the Sitest program S tudent Guide SIPLACE D4 (FSE) Sitest EN 09/2006 306 12.3.10.2 Function Firmware download X Select Settings from the SITEST menu and t…

Sitest
New function in the Sitest program Basic description of all calibration steps
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Sitest
305
12.3.10 New function in the Sitest program
12.3.10.1 Menu of transport
12.3 - 6: Transport - option and configuration
Legend
1.
Changing the conveyor width
(only for lane 1, if dual conveyor):
You will see a submenu, in which you can select
Widened
or
Not widened
(standard width).
Widened means that lane 2 is moved together (to the limit switch), while the fixed side for lane 1
remains in its position. (max. width of lane 1 = 380 mm)
If point 4 is selected first (excess width) this gives a max. width for lane 1 of 430 mm.
2.
Change transport mode
:
This function is used to configure the option
Long Board
.
Next menu:
normal PCB/ long PCB
3.
Show stop positions
:
shows the number of position in PA 1 and PA2, additional the offset depend on the standard position
(PCB Reference- corner). The offset for the option
Long Board
is set by SIPLACE Pro.
4. This enables you to move the fixed conveyor side in its standard position to accommodate standard
or excess width boards (values from the conveyor control machine data).
Excess width means that the fixed side is moved up to 26 mm. (dual conveyor lane 1 and lane 2 =
242 mm, flexible dual conveyor lane 1 = 430 mm, single conveyor = 508 mm)
5. Point 5 and 6 only with Siemens Service Passwort active! The fixed conveyor side (
left, right
) can
be taught.
6. Save the teach data from point 5.

Sitest
Basic description of all calibration steps New function in the Sitest program
Student Guide SIPLACE D4 (FSE)
Sitest EN 09/2006
306
12.3.10.2 Function Firmware download
X Select
Settings
from the SITEST menu and then
Firmware
Download
.
12.3 - 7: Overview of firmware download
12.3 - 8: Firmware download
In the Can FW folder there are all current Firmware versions of all axes, tables etc.

Sitest
New function in the Sitest program Basic description of all calibration steps
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Sitest
307
Legend
1. The system checks this folder, to see whether there is a newer version of the firmware for the
respective axis, table etc.. If there exist a new firmware version, this new version will be offered and
could be downloaded for example to the star- axis.
2. You can also copy a new firmware version manually into the CAN FW folder. Click on the
Copy firm-
ware file to pool
. An Explorer menu will open, in which you can directly copy the new firmware
version from a USB stick etc. into the CAN FW folder. This one inserted by you is now present in the
selection menu (see (1)).
12.3.10.3 Head Modularity for SIPLACE D4
X Select
Settings
from the SITEST menu and then
Head exchange
.
12.3.10.3.1 Head data
12.3 - 9: Head modularity - head data
Legend
1. Select and set the relevant head type for the head replacement.
2. Select and set the relevant camera type for the selected head type or head replacement.
3. Shows the data for the head installed. The current BIOS and application version, the head type and
the camera type of the installed head.