Communication and Control CAN Bus CAN I/O Module (SLIO) - SIPLACE D4 S tudent Guide SIPLACE D4 (FSE) Communication and Control EN 09/2006 86 4.3.6.1 I/O module, main distributor (input s) nc= not connected (Reserve) Term…

100%1 / 340
Communication and Control
CAN I/O Module (SLIO) - SIPLACE D4 CAN Bus
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Communication and Control
85
There is an 8-fold DIP switch on the I/O module.
4.3 - 15: DIP Switch on the Main- and Sub Distributor
4.3 - 16: Overview CAN I/O module
Legend
Jumper on the rear side, activates the RS232 interface for service purposes
X1 CAN interface X2 Analog interface, bootstraploader interface
X3, X4, X5 Digital inputs 24V X6 Power supply 5V
X7, X8 Digital outputs 24V X9 Power supply 24V
RS232 Analog interface, bootstraploader
interface
Communication and Control
CAN Bus CAN I/O Module (SLIO) - SIPLACE D4
Student Guide SIPLACE D4 (FSE)
Communication and Control EN 09/2006
86
4.3.6.1 I/O module, main distributor (inputs)
nc= not connected (Reserve)
Terminals I / O Description / Note
IO2 Di0 nc (Reserve) (X3rb_1)
IO2 Di1 nc (Reserve) (X3rb_2)
IO2 Di2 nc (Reserve) (X3rb_3)
IO2 Di3 nc (Reserve) (X3rb_4)
IO2 Di4 nc (Reserve) (X3rb_5)
IO2 Di5 M_DruckSensorHauptventil
When the preset air pressure is reached, a "high“ acknowledges the state
"Compressed air level reached“.
(X3rb_6)
IO2 Di6 nc (Reserve) (X3rb_7)
IO2 Di7 nc (Reserve) (X3rb_8)
IO2 Di8 M_Pip.links (auf)_2a
"high“ if nozzle changer is open
(X4rb_1)
IO2 Di9 M_Pip.rechts (zu)_2a
"high“ if nozzle changer is closed
(X4rb_2)
IO2 Di10 M_Pip.links (auf)_2b
"high“ if nozzle changer is open
(X4rb_3)
IO2 Di11 M_Pip.rechts (zu)_2b
"high“ if nozzle changer is closed
(X4rb_4)
IO2 Di12 M_Pip.links (auf)_3a
"high“ if nozzle changer is open
(X4rb_5)
IO2 Di13 M_Pip.rechts (zu)_3a
"high“ if nozzle changer is closed
(X4rb_6)
IO2 Di14 M_Pip.links (auf)_3b
"high“ if nozzle changer is open
(X4rb_7)
IO2 Di15 M_Pip.rechts (zu)_3b
"high“ if nozzle changer is closed
(X4rb_8)
IO2 Di16 nc (Reserve) (X5rb_1)
IO2 Di17 nc (Reserve) (X5rb_2)
IO2 Di18 nc (Reserve) (X5rb_3)
IO2 Di19 nc (Reserve) (X5rb_4)
IO2 Di20 nc (Reserve) (X5rb_5)
IO2 Di21 nc (Reserve) (X5rb_6)
IO2 Di22 nc (Reserve) (X5rb_7)
IO2 Di23 nc (Reserve) (X5rb_8)
Communication and Control
CAN I/O Module (SLIO) - SIPLACE D4 CAN Bus
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Communication and Control
87
4.3.6.2 I/O Module for Main Distributor (Outputs)
nc= not connected (Reserve)
Terminals I / O Description / Note
IO2 Do0 nc (Reserve) (X7rb_1)
IO2 Do1 nc (Reserve) (X7rb_2)
IO2 Do2 nc (Reserve) (X7rb_3)
IO2 Do3 nc (Reserve) (X7rb_4)
IO2 Do4 nc (Reserve) (X7rb_5)
IO2 Do5 St_DruckluftHauptventil
A "low" signal opens the compressed air main valve. A "high" then
closes off the compressed air supply.
(X7rb_6)
IO2 Do6 nc (Reserve) (X7rb_7)
IO2 Do7 nc (Reserve) (X7rb_8)
IO2 Do8 St_VentilPipetten_2a
“high” signal opens the nozzle changer.
(X8rb_1)
IO2 Do9 St_VentilPipetten_2b
“high” signal opens the nozzle changer.
(X8rb_2)
IO2 Do10 St_VentilPipetten_3a
“high” signal opens the nozzle changer.
(X8rb_3)
IO2 Do11 St_VentilPipetten_3b
“high” signal opens the nozzle changer.
(X8rb_4)
IO2 Do12 St_GrüneLampe1
The right-hand green lamp indicates "high" at the port output.
Definition: flashes when no board is in the (right) conveyor lane
(X8rb_5)
IO2 Do13 St_StörLampe1
The right-hand white lamp indicates "high" at the port output.
Definition: Fault on a feeder on location 1 or 2.
(X8rb_6)
IO2 Do14 St_StörLampe2
The left white lamp indicates "high" at the port output.
Definition: Fault on a feeder on location 3 or 4.
(X8rb_7)
IO2 Do15 St_GrüneLampe2
The left green lamp indicates "high" at the port output.
Definition: flashes when no board is in the (left) conveyor lane
(X8rb_8)