5OM-1075-002.pdf - 第41页
Section 3 Location of Sensors and Loads 0308-003 B(M750JG---2102) 3-6 AHB01EMTP Layout of Sensors and Loads (Cover Section) Maintenance Opening Detection A Maintenance Opening Detection B Symbol Name BPH082A T (Light Pro…

Section 3 Location of Sensors and Loads
0107-001-(M750JF---2102) 3-5 AHB01EMTP
Layout of Sensors and Loads (Nozzle Stocker (B2))

Section 3 Location of Sensors and Loads
0308-003 B(M750JG---2102) 3-6 AHB01EMTP
Layout of Sensors and Loads (Cover Section)
Maintenance Opening Detection A
Maintenance Opening Detection B
Symbol Name
BPH082AT (Light Projecting)
BPH082AR (Light Receiving)
BPH082BT (Light Projecting)
BPH082BR (Light Receiving)
YSOL01 (SQ1)
YSOL02 (SQ2)
YSOL03 (SQ3)
YSOL04 (SQ4)
YSOL05 (SQ5)
Note
Safety Door Electromagnetic Lock A
Safety Door Electromagnetic Lock B
Feeder Base #1 Pullout Prevention Bar
Electromagnetic Lock
Feeder Base #3 Pullout Prevention Bar
Electromagnetic Lock
Feeder Base #4 Pullout Prevention Bar
Electromagnetic Lock
(Light Projecting)
(Light Projecting)
(Light Receiving)
(Light Receiving)

Section 3 Location of Sensors and Loads
0107-001-(M750JMB--2101) 3-7 AHB01EMTP
Layout of Sensors and Loads (Head (L))