C-ATS_cwd_je.pdf - 第3页
T able of contents /目次 C-A TS P. 1 Interfacecircuit/インターフェース回路図 P. 2 Powercircuit/電源回路図 P. 3 Emergencycircuit/非常停止回路図 P.4 Safetyprogram/安全コントローラー接続図 P. 5 Servocontoroller/�…

Safety.
To replace the purchased parts safely, be sure to comply with the following items.
However the following cannot cover all items regarding safety in detail. So it is
extremely important that the worker or person handling the machine make correct
decisions regarding safety.
CAUTION Machine operation of operator•Work is limited to maintenance and
safety skill.
Be sure to turn off the machine’s power supply before doing the exchange work.
Be sure to push the emergency stop SW, and do adjustment work under the
emergency stop condition.
Refer to the manual for the replacement work of each consumable part.
*
Safety alert symbols and signal words
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor
injury, or material loss or damage to the machine. These points are important for
protecting the safety of the machine and data, etc.
安全について
お買い上げいただいたパーツを安全に交換していただくために、下記の事項は必ず守って作
業を行ってください。しかしながら、下記に全ての安全性に関する項目を細部にわたり網羅
することは困難です。従って作業者自身の安全に対する正確な判断が非常に大切な要素とな
りますことをご留意ください。
注意 作業者は本機の動作・メンテナンスに習熟していて安全に作業を行える方に限り
ます。
①交換作業は、マシンの電源を切ってから必ず行ってください。
②調整作業は、非常停止 SW を押し、非常停止状態で必ず行ってください。
③消耗品の交換、各メンテナンス作業についてはマニュアルをご参照ください。
※安全標記の 注意は取り扱いを誤った場合、傷害に至る可能性または物的損害の発生
が想定される内容を示しています。本体およびデータなどの損傷を防ぐために重要な注
意事項です。
Table of contents
/目次
C-ATS
P. 1 Interfacecircuit/インターフェース回路図
P. 2 Powercircuit/電源回路図
P. 3 Emergencycircuit/非常停止回路図
P.4 Safetyprogram/安全コントローラー接続図
P. 5 Servocontoroller/サーボコントローラー接続図
P. 6 FDRCtrlbrdassy/FDRコントロールボード接続図
P. 7 Safetyunit /安全ユニット接続図
P. 8 Indicatorassysel/表示装置接続図
P. 9 AZinterlockcircuit/AZ 連動回路図
P.10Aircircuit/ エアー回路図
P.11Wiringpartslist /配線部品表
Condential & Proprietary

Confidential & Proprietary
PAGE
See MOUNTOR
INTERCONNECTION DIAGRAM
See MOUNTOR
INTERCONNECTION DIAGRAM I/O B
SYSTEM CONTROLLER
SERVO BOARD 2
CART 4
CART 5
CART 6
CART 7
CART B
SET POS
FES EMG
CART A
I/O
SET POS
F FES EMG
F ATS
I/O B
F CART B
F CART A
See MOUNTOR
INTERCONNECTION DIAGRAM KM17A AC212V
KM17 AC230V
HD CONNECTOR ASSY
CART 1
CART 2
CART 3
ATS PWR
FDR PWR
CART+24V
MOUNTOR REAR
R ATS PWR
R FDR PWR
R CART+24V
HD CONNECTOR ASSY
ATS 1 J0831 AC230V
AC212V
ATS 2
ATS 3
J0833
FDR CTRL PWR
ATS SAFE
SERVO ON
Connection at HD CONNECTOR ASSY.
C-ATS
C-ATS
CART 8
See MOUNTOR
INTERCONNECTION DIAGRAM
See MOUNTOR
INTERCONNECTION DIAGRAM
KM16 AC230V
KM16A AC212V
KM17A FDR DC24V
KM16A FDR DC24V
See MOUNTOR
INTERCONNECTION DIAGRAM
I/O CONVEYOR BOARD
CN21
HD CONNECTOR ASSY
CART 1
CART 2
CART 3
ATS PWR
FDR PWR
CART+24V
MOUNTOR FRONT
F ATS PWR
F FDR PWR
F CART+24V
MAIN MACHINE
See MOUNTOR
INTERCONNECTION DIAGRAM
See MOUNTOR
INTERCONNECTION DIAGRAM
SYSTEM CONTROLLER
I/O C
SERVO BOARD 4
See MOUNTOR
INTERCONNECTION DIAGRAM KM14,KM17 IO DC24V
KM12,KM16 IO DC24V
CART 4
CART 5
CART 6
CART 7
CART B
SET POS
FES EMG
CART A
I/O
SET POS
R FES EMG
R ATS
R CART A
R CART B
Note : Harnesses with short dashed line are included in the mounter.
Please refer to the mounter interconnection diagram.
I/O C CART 8
ATS 4
ATS 5
ATS 6
ATS 7
ATS 8
J0832
J0834LAN
J0889
MKY
DI/DO
SAFETY PROGRAM
SAFETY UNIT
INDICATOR ASSY SEL
AZ INTERLOCK CIRCUIT
POWER CIRCUIT
See Page 2
FDR CTRL BRD ASSY
See Page 6
MAGAZINE-1 DOOR
MAGAZINE-2 DOOR
NON-STOP SUPPLY DOOR
J0887
J0886
J0885J0890
COVER EARTH
FRONT EL BOX
SERVO CONTROLLER
See Page 5
See Page 4
See Page 7
See Page 8
See Page 9
EMERGENCY CIRCUIT
See Page 3
See MOUNTOR
INTERCONNECTION DIAGRAM
KM10
LAN
LAN
LAN
CC.V3
1
INTERFACE CIRCUIT
C-ATS