00198761-01_SM_Head_Care_Station_II_EN - 第19页

3 Preparatory work... 3.1 Turn off and disconnect the HCS II Service Manual SIPLACE Head Care Station II 11/2019 19 3 Preparatory work... DANGER Observe safety instructions! ► Please observe the safety instructions in th…

100%1 / 68
2 Spare parts overview
2.4 List of all spare parts
18 Service Manual SIPLACE Head Care Station II 11/2019
3 Preparatory work...
3.1 Turn off and disconnect the HCS II
Service Manual SIPLACE Head Care Station II 11/2019 19
3 Preparatory work...
DANGER
Observe safety instructions!
Please observe the safety instructions in this Service Manual and in the HCSII User
Manual for all work!
NOTICE
Observe the detailed circuit diagrams!
For more detailed information refer to the circuit diagrams folder of the HCSII.
Detailed circuit diagrams folder for HCSII [DEEN:00198762‑xx]
3.1 Turn off and disconnect the HCS II
DANGER
Nonobservance may cause injury to personnel and damage to the HCS II!
Before performing any service work on the HCS II, the following steps must be per-
form.
End all verification operations at the HCS II.
Close the SIPLACE Test Bench software.
Shut down the Windows operating system correctly, otherwise problems may occur when
restarting or data may be lost.
Switch off the HCS II at the main switch.
Disconnect the HCS II from the main power supply.
Disconnect the HCS II from the compressed air supply.
3.2 Equipment and tools
Equipment and tools needed to prepare the HCS II Head Unit for service work:
00353832‑xx Allen key set 2 mm, 2.5 mm
00376516-xx Socket wrench set 7 mm
00096290-xx Spanner wrench set 7 mm
00319064-xx Screwdriver Size 1
00318673-xx Side cutter electronic size 110
00096487-xx POINT PLIERS 140mm OVAL
00308458-xx Cable ties B=2.5mm, L=102mm Panduit
3 Preparatory work...
3.3 Access to the spare parts of the HCS II Head Unit
20 Service Manual SIPLACE Head Care Station II 11/2019
3.3 Access to the spare parts of the HCS II Head Unit
Fig.8: Remove covers
Dismantle the placement head if avail-
able.
Remove the cover(1).
Disconnect the flat ribbon cables be-
hind the cover.
Remove the five screws(2) fixing the
back cover(3) and put it down.
Fig.9: Remove covers
The back cover(1) is connected to the Head
Unit by a cable to the safety switch(2) and
an grounding cable(3).
Unplug the cable to the safety
switch(2).
You may want to remove the grounding
cable(3) for a better handling of the
Head Unit.