00198761-01_SM_Head_Care_Station_II_EN - 第30页

4 Service work – HCSII Head Unit 4.6 Replacing the Base Adapter C&P / MHCU 30 Service Manual SIPLACE Head Care Station II 11/2019 Removal ► Open any cable ties where necessary. You may want to mark the positions of …

100%1 / 68
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
Service Manual SIPLACE Head Care Station II 11/2019 29
4.6 Replacing the Base Adapter C&P / MHCU
Parts
Fig.27: PCB Base Adapter C&P HCS2.3
PCB Base Adapter C&P HCS2.3
[03158917‑xx]
Fig.28: MHCU complete compatible
MHCU complete compatible
[03090990‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the compressed air filter. See 4.2 "Replacing the compressed air filter" [}24].
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
30 Service Manual SIPLACE Head Care Station II 11/2019
Removal
Open any cable ties where necessary. You may want to mark the positions of the relevant
connections to make clear assignment easier later on.
Fig.29: Removal 1
Unplug the two flat ribbon cables(1)
from the Board adapter(2).
Unplug the round cable X90(3) from
the Board Adapter Head Interface(4)
(main PCB at the back side).
Unplug the black cable X5(5) from the
Modul Head Interface(6).
(Unlock the plug by pressing both
sides.)
Unplug the two flat ribbon cables X1/
X2(7) from the Base Adapter(8).
(The plugs are locked on both sides.)
Fig.30: Removal 2
Remove the two screws(1) fastening
the Base Adapter C&P(3) assembly
bracket on the right side.
Make sure that the screws are not lost.
Loosen the two screws(2) (keyholes,
do not remove the screws!) fastening
the Base Adapter C&P(3) assembly
bracket on the left side.
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
Service Manual SIPLACE Head Care Station II 11/2019 31
Fig.31: Removal 3
Carefully move the Base Adapter C&P
a bit out (slight rotating movement).
Unplug the pressure sensor X10(1).
Unthread the round cable X90 and
carefully remove the Base Adapter
C&P from the HCS.
Fig.32: Removal 4
Remove the three screws fastening the
two assembly brackets(1) and(2).
Fig.33: Base Adapter C&P (upper side)
Fig.34: Base Adapter C&P (under side)
1 PCB Base Adapter C&P HCS2.3
[03158917‑xx]
2 MHCU complete compatible
[03090990‑xx]
3 Board Adapter-LP CPP/C&P20-HCSII
[03087843‑xx]
4 Round cable X90
5 Screws fastening the MHCU
Remove the Board Adapter-LP CPP/C&P20-HCSII(3).
4.7 "Replacing the Board Adapter LP CPP/C&P20" [}33].