00198761-01_SM_Head_Care_Station_II_EN - 第32页

4 Service work – HCSII Head Unit 4.6 Replacing the Base Adapter C&P / MHCU 32 Service Manual SIPLACE Head Care Station II 11/2019 Replacing/Converting the MHCUs ► Remove the screws (5) on the back of the board fast…

100%1 / 68
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
Service Manual SIPLACE Head Care Station II 11/2019 31
Fig.31: Removal 3
Carefully move the Base Adapter C&P
a bit out (slight rotating movement).
Unplug the pressure sensor X10(1).
Unthread the round cable X90 and
carefully remove the Base Adapter
C&P from the HCS.
Fig.32: Removal 4
Remove the three screws fastening the
two assembly brackets(1) and(2).
Fig.33: Base Adapter C&P (upper side)
Fig.34: Base Adapter C&P (under side)
1 PCB Base Adapter C&P HCS2.3
[03158917‑xx]
2 MHCU complete compatible
[03090990‑xx]
3 Board Adapter-LP CPP/C&P20-HCSII
[03087843‑xx]
4 Round cable X90
5 Screws fastening the MHCU
Remove the Board Adapter-LP CPP/C&P20-HCSII(3).
4.7 "Replacing the Board Adapter LP CPP/C&P20" [}33].
4 Service work – HCSII Head Unit
4.6 Replacing the Base Adapter C&P / MHCU
32 Service Manual SIPLACE Head Care Station II 11/2019
Replacing/Converting the MHCUs
Remove the screws(5) on the back of the board fastening the MHCU(2) and carefully pull the
MHCU off the base adapter.
CAUTION
Washers/Pins
Make sure not to loose the washers.
Make sure not to damage the pins under the MHCU.
Installation
Fig.35: Installation
Install the two assembly brackets on
the Base Adapter.
Make sure that the assembly brackets
flush with the frame.
To make installation easier, turn the
two screws at the smaller assembly
bracket out until they are barely visible
at the nuts.
Install the Board Adapter-LP CPP/C&P20-HCSII.
4.7 "Replacing the Board Adapter LP CPP/C&P20" [}33].
Insert the Base Adapter C&P into the HCS and thread in the round cable X90.
Plug in the pressure sensor X10.
Thread in the two screws on the left into the keyholes.
Loosely insert the two screws on the right (the front one first).
Push the Base Adapter C&P to the back and fasten the four screws.
Plug in the two flat ribbon cables X1/X2 on the Base Adapter C&P.
(Make sure the plugs are locked on both sides.)
Plug in the black cable X5 at the Modul Head Interface.
Plug in the round cable X90 at the Board Adapter Head Interface (main PCB at the back side).
Plug in the two flat ribbon cables at the Board adapter.
Replace any cable ties which you have removed.
4 Service work – HCSII Head Unit
4.7 Replacing the Board Adapter LP CPP/C&P20
Service Manual SIPLACE Head Care Station II 11/2019 33
4.7 Replacing the Board Adapter LP CPP/C&P20
Parts
Fig.36: Board Adapter-LP CPP/C&P20 HCSII
Board Adapter-LP CPP/C&P20 HCSII
[03087843‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Removal
Fig.37: Removal
Unplug the flat ribbon cables
Remove the four screws(1) fastening
the Board Adapter-LP CPP/C&P20 on
the Base Adapter C&P.
Hold the screw nuts(2) from behind
(e.g.with tweezers).
Make sure that the screws and screw
nuts are not lost.
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.