4 Service work – HCSII Head Unit 4.14 Replacing the Board Adapter Head Interface C700B Service Manual SIPLACE Head Care Station II 11/2019 43 Removal Fig.57: Removal (from behind) Fig.58: Removal (from front) ► Remove…

4 Service work – HCSII Head Unit
4.14 Replacing the Board Adapter Head Interface C700B
42 Service Manual SIPLACE Head Care Station II 11/2019
4.14 Replacing the Board Adapter Head Interface C700B
Parts
Fig.56: Board Adapter Head Interface
●
Board Adapter Head Interface
[03085198‑xx]
Preparatory work...
► Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
► Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
► Remove the contactors K3 and K4. See 3.5 "Remove the contactors K3 and K4" [}22].
► Remove the compressed air filter. See 4.2 "Replacing the compressed air filter" [}24].
► Remove the PCB Base Adapter Twin. See 4.4 "Replacing the Base Adapter Twin /
MHCU" [}26].
► Remove the PCB Base Adapter C&P. See 4.6 "Replacing the Base Adapter C&P /
MHCU" [}29].
► Remove the Modul Head Interface-C700B. See 4.8 "Replacing the Head Interface-
C700B" [}34].
► Remove the Head Care Interface with the LabJack. See 4.12 "Replacing the Head Care Inter-
face" [}38].

4 Service work – HCSII Head Unit
4.14 Replacing the Board Adapter Head Interface C700B
Service Manual SIPLACE Head Care Station II 11/2019 43
Removal
Fig.57: Removal (from behind)
Fig.58: Removal (from front)
► Remove the seven screws fastening the
Board Adapter Head Interface(1) on the
frame. Make sure that the screws are not
lost.
Fig.59: Board Adapter Head Interface with Flat ribbon cable
1. Board Adapter Head Interface
2. Flat ribbon cable

4 Service work – HCSII Head Unit
4.15 Replacing the Safety Switch (S10)
44 Service Manual SIPLACE Head Care Station II 11/2019
Fig.60: Removed
The Board Adapter Head Interface is
removed
Installation
► Follow the removal instructions in reverse order for installation.
► Replace any cable ties which you have removed.
4.15 Replacing the Safety Switch (S10)
Parts
Fig.61: Safety Switch-S10
●
Safety Switch-S10 [03152714‑xx]
Preparatory work...
► Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
► Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
► Remove the Modul Head Interface-C700B. See 4.8 "Replacing the Head Interface-
C700B" [}34].