00198761-01_SM_Head_Care_Station_II_EN - 第43页

4 Service work – HCSII Head Unit 4.14 Replacing the Board Adapter Head Interface C700B Service Manual SIPLACE Head Care Station II 11/2019 43 Removal Fig.57: Removal (from behind) Fig.58: Removal (from front) ► Remove…

100%1 / 68
4 Service work – HCSII Head Unit
4.14 Replacing the Board Adapter Head Interface C700B
42 Service Manual SIPLACE Head Care Station II 11/2019
4.14 Replacing the Board Adapter Head Interface C700B
Parts
Fig.56: Board Adapter Head Interface
Board Adapter Head Interface
[03085198‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the contactors K3 and K4. See 3.5 "Remove the contactors K3 and K4" [}22].
Remove the compressed air filter. See 4.2 "Replacing the compressed air filter" [}24].
Remove the PCB Base Adapter Twin. See 4.4 "Replacing the Base Adapter Twin /
MHCU" [}26].
Remove the PCB Base Adapter C&P. See 4.6 "Replacing the Base Adapter C&P /
MHCU" [}29].
Remove the Modul Head Interface-C700B. See 4.8 "Replacing the Head Interface-
C700B" [}34].
Remove the Head Care Interface with the LabJack. See 4.12 "Replacing the Head Care Inter-
face" [}38].
4 Service work – HCSII Head Unit
4.14 Replacing the Board Adapter Head Interface C700B
Service Manual SIPLACE Head Care Station II 11/2019 43
Removal
Fig.57: Removal (from behind)
Fig.58: Removal (from front)
Remove the seven screws fastening the
Board Adapter Head Interface(1) on the
frame. Make sure that the screws are not
lost.
Fig.59: Board Adapter Head Interface with Flat ribbon cable
1. Board Adapter Head Interface
2. Flat ribbon cable
4 Service work – HCSII Head Unit
4.15 Replacing the Safety Switch (S10)
44 Service Manual SIPLACE Head Care Station II 11/2019
Fig.60: Removed
The Board Adapter Head Interface is
removed
Installation
Follow the removal instructions in reverse order for installation.
Replace any cable ties which you have removed.
4.15 Replacing the Safety Switch (S10)
Parts
Fig.61: Safety Switch-S10
Safety Switch-S10 [03152714‑xx]
Preparatory work...
Turn off and disconnect the HCS II. See 3.1 "Turn off and disconnect the HCS II" [}19].
Perform the steps described in section 3.3 "Access to the spare parts of the HCS II Head
Unit" [}20].
Remove the Modul Head Interface-C700B. See 4.8 "Replacing the Head Interface-
C700B" [}34].