80S-20用户手册 - 第164页
4 Placement functions SIPLACE 80S-20 /F4 User Manual 4.3 Feeders Soft ware version S R.407.xx 01/2001 US Edition 164 4 Fig. 4.3 - 1 "Empty t racks" view Key to Fig. 4.3 - 1 (1) "Empt y tr acks" view (…

SIPLACE 80S-20/F4 User Manual 4 Placement functions
Software version SR.407.xx 01/2001 US Edition 4.3 Feeders
163
4.3 Feeders
Å Click on the icon in the toolbar in the Main view.
The user interface switches to one of the views described in the following sections.
NOTE
When the "Feeders" menu function is called for the first time after starting the SC software, then
the "Empty tracks" view is displayed first (see Fig. 4.3 - 1). 4
4.3.1 "Empty tracks" view
If the placement head cannot pick a component from a track after 3 attempts, then it will not use
this track again. This track is added to the "Empty tracks" list.
As soon as the feeders or waffle pack trays in the empty tracks are filled with components, this
fact must be confirmed so that the placement head can access these tracks again. This is done
by refilling the empty tracks using the "Refill track" function. You can refill individual tracks or all
tracks of a location at the same time when refilling empty tracks with "Refill track". 4
NOTE
The manual refilling of tracks that contain components with specified component barcodes is only
possible using "Refill track" when the "Component verification with barcode" option in the machine
options is not
active.
If the "Component verification with barcode" option is active, then a corresponding note is dis-
played instead of the buttons for locations 1 through 4 (see Fig. 4.3 - 2). 4
4
Å Click on the icon, if necessary.
The "Empty tracks" view is displayed (see Fig. 4.3 - 1
).
4
4

SIPLACE 80S-20/F4 User Manual 4 Placement functions
Software version SR.407.xx 01/2001 US Edition 4.3 Feeders
165
4
Fig. 4.3 - 2 "Empty tracks" view when the "Component verification with barcode" option is active
4
4.3.1.1 Meaning of the entries in the table "Empty tracks"
– Loc.
Number of the location whose track is "empty".
– Tr D T
Number of the "empty" track and of the feeder division or number of the waffle pack tray com-
partment and the level in the waffle pack changer for the corresponding component
– CmpName
Name of the corresponding component.
– Track barc.
The track barcode assigned to the corresponding track is entered in this column.