80S-20用户手册 - 第368页

7 What should you do ... SIPLACE 80S-20 /F4 User Manual 7.1 Switching on the SIPLACE line Software version SR.407.xx 01/2001 US Edition 368 NOTE The curren t state of the station is dis played in the status field in the …

100%1 / 570
SIPLACE 80S-20/F4 User Manual 7 What should you do ...
Software version SR.407.xx 01/2001 US Edition 7.1 Switching on the SIPLACE line
367
7.1.3 Switching on the station/starting the user interface of the station computer
program
ATTENTION
Switch on the station only after the desktop is displayed on the line computer monitor. Otherwise,
communication problems may occur. 7
Å Switch on the station on the main switch and check to see if the manometer displays the re-
quired operating pressure after you have switched the station on.
The station computer software is uploaded. When the line computer is connected and commu-
nication is error-free, the Main view of the station computer user interface appears for the "Op-
erator" user class after approximately 2 minutes (see Fig. 7.1 - 1
).
7
Fig. 7.1 - 1 Main view after loading the station computer software
7 What should you do ... SIPLACE 80S-20/F4 User Manual
7.1 Switching on the SIPLACE line Software version SR.407.xx 01/2001 US Edition
368
NOTE
The current state of the station is displayed in the status field in the "State" line, and the action you
are to execute is displayed in the "Action:" line (see Fig. 7.1 - 1). 7
Å Press one of the start keys (white) when prompted with "Press start key".
(The start keys are located on the input side and output side of the placement system.)
A reference sequence is executed on all axes. The station is ready for operation after the ref-
erence sequence has completed.
The symbol is displayed in the work area of the user interface.
7
7
7
7.1.4 "Switching on the SIPLACE line" flow chart
The following flow chart shows the actions executed be the line computer, station and operator
while the SIPLACE line is being switched on and started up. 7
7
SIPLACE 80S-20/F4 User Manual 7 What should you do ...
Software version SR.407.xx 01/2001 US Edition 7.1 Switching on the SIPLACE line
369
7
Fig. 7.1 - 2 "Switching on the SIPLACE line flow chart
Test set-up
Reset tracks
No
Line computer tasks
Load cluster data
Fiducials
OK?
Make settings on the machine
Set-up generator appears
Check the set-up
(insert feeders)
Switch on
Nozzle check
Change nozzle
configuration, if necessary
Wait for PCB
Introduce PCB
Track
errors
Yes
Abort
placement
Yes
PCB onto output conveyor
No
Station computer
Bold :
Italic :
To be carried out
by the operator
Carried out or
signaled by the
station
Confirm the
set-up generator