80S-20用户手册 - 第46页

1 Introduction SIPLACE 80S-20 /F4 User Manual 1.10 Setting up the placement machine Sof tware version SR.407.xx 01/2001 US Edition 46 1.10 Setting up the placeme nt machine 1.10.1 T ransport dimensions 1 Fig. 1.10 - 1 Di…

100%1 / 570
SIPLACE 80S-20/F4 User Manual 1 Introduction
Software version SR.407.xx 01/2001 US Edition 1.9 Dimensions and weight of the machine
45
1.9.3 Center of gravity of the machine
1
Fig. 1.9 - 2 Center of gravity of the machine
X coordinate - 80 mm
Y coordinate 0 mm
Z coordinate 350 mm high
T PCB transport direction 1
1
These center of gravity coordinates relate to machines with a PCB transport height of 830 mm.1
1 Introduction SIPLACE 80S-20/F4 User Manual
1.10 Setting up the placement machine Software version SR.407.xx 01/2001 US Edition
46
1.10 Setting up the placement machine
1.10.1 Transport dimensions
1
Fig. 1.10 - 1 Dimensions of the placement machine during transportation and setting up
A Points for attaching the pallet jack (fork length 1600 mm) 1
(1) Length 1587 mm
(2) Width 1921 mm
(3) Height 1836 mm
(4) Input conveyor
(5) Output conveyor
1
The PCB transport height is 830 mm ± 15 mm. 1
SIPLACE 80S-20/F4 User Manual 1 Introduction
Software version SR.407.xx 01/2001 US Edition 1.10 Setting up the placement machine
47
1.10.2 Transport configuration and transportation
The following components are not installed when the placement machine is delivered from the fac-
tory: 1
Keyboards
Monitors
Fault indicator lamps and
Changeover tables
Å Install the dismantled components for commissioning.
Å Use a pallet jack with a minimum fork length of 1600 mm to transport the machine.
Å Attach the pallet jack only at the indicated points.
1.10.3 Quality of the foundation
Å Ensure that
you set up the machine on a firm and non-vibrating foundation.
the load bearing capacity per unit area of the foundation is greater than 1000 kg/m².
1.10.4 Compressed air supply
The pressure of the compressed air supply must be at least 5.5 bar (max. permissible value
8bar).
The compressed air must conform to the above specification.
This can be achieved with 1
Oil-free compressors, e.g. Atlas, Copco type ZR4
Compressed air washer/dryers
Micro-filters, series X, e.g. from Zander
1.10.5 Power supply
The power socket must be fused with the following fuse ratings:
3 x 16 A for 3 x 400 VAC / 3 x 208 VAC 1