80S-20用户手册 - 第525页

SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware Software vers ion SR.407.xx 0 1/2001 US Edition 11.11 Feeder position recognition 525 If the clu ster data contains an entry for a track, the PCB camera on th…

100%1 / 570
11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.11 Feeder position recognition Software version SR.407.xx 01/2001 US Edition
524
11.11 Feeder position recognition
11.11.1 General
A feeder can be measured if it is equipped with position fiducials. 11
This function can also be used with the waffle tray holder (manual tray) if it has position fiducials. 11
If the Feeder position recognition function is selected on the line computer, this function will ap-
pear in the machine options. 11
You can then activate or deactivate feeder position recognition at each station from the machine
options. 11
.
Fig. 11.11 - 1 Feeder position recognition
PLEASE NOTE:
The feeder position recognition function is always inactive when the station is switched on. 11
SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.11 Feeder position recognition
525
If the cluster data contains an entry for a track, the PCB camera on the feeder moves to the posi-
tion of the centering fiducial. Any centering fiducial offset determined by measurement is allocated
to this track, and added to the pick-up position during the pick-up process. 11
11.11.1.1 Restrictions
Feeder position recognition cannot be used for WPC trays that are set up in the wafflepack
changer.
Up to three fiducial positions can be defined for each feeder.
Feeder fiducials on the right-hand side of the table (viewed in the transport direction) cannot
be measured on the 80F.
PLEASE NOTE:
This restriction does not apply to machines with a sub-gantry camera. 11
If there is a feeder at location 118, and the fiducial position of the outer pick-up division is closer
to the X-axis travel range limit than the pick-up position, then the 8 mm S tape and bulk case
feeder cannot be scanned.
11
11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.12 Fine calibration Software version SR.407.xx 01/2001 US Edition
526
11.12 Fine calibration
11.12.1 Overview
Fine calibration involves measuring the machines placement offset and determining the required
correction from this value. The Fine calibration measuring program is integrated into the SITEST
program, and a detailed description of the measuring procedure is given in the Fine calibration
instructions (article no. 00191655-01). 11
CAUTION
The SITEST program is password-protected. It must only be called up and used by Siemens en-
gineers or appropriately trained personnel. 11
11.12.2 System requirements
The following system requirements must be fulfilled in order to use the fine calibration program:11
Machine type S-20/F
4
Station computer software version 406.xx or later
SITEST version 406.xx or later
11.12.3 Measuring equipment and tools
The following are supplied as standard: 11
Mapping plate (glass plate in a metal frame)
Double-sided transparent adhesive film
Lighting unit
Magazine with glass components for the collect&place head and pick&place head with fine-
pitch vision module.
11
The following items must be ordered: 11
Manual tray (waffle tray holder) to hold the magazine for the glass components
(article number 00116430-xx)
11
11