EN 3.pdf - 第139页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.9 DOCKING CART & FEEDER BASE V ersion 01 Tit le FEEDER BASE SYSTEM OPTION CHANGE Page 3-9-6 Note [FEEDER BASE SYSTEM OPTION CHANGE] 1. Select <Sys.Setup> → &l…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.9 DOCKING CART & FEEDER BASE
Version
01
Title
FEEDER BASE SLOT SETTING
Page
3-9-5
Note
For two Fix Cameras
Camera Setting → Camera Select → Fix Cam1 → Setting (Slot 32~39, 40~45)

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.9 DOCKING CART & FEEDER BASE
Version
01
Title
FEEDER BASE SYSTEM OPTION CHANGE
Page
3-9-6
Note
[FEEDER BASE SYSTEM OPTION CHANGE]
1. Select <Sys.Setup> → <F10 Pref>. → <Device> → <Feeder Base System Option>: <SM Docking 56> and
→ click on <Update>.
2. Select <Diagnosis> → <F2 I/O> → <Feeder Ba se IO> to see if operates properly.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.9 DOCKING CART & FEEDER BASE
Version
01
Title
FEEDER CHAGE LOCATION CHANGE
Page
3-9-7
Note
[FEEDER CHAGE LOCATION CHANGE]
1. Select <Sys. Setup> → <F2. Head>.
2. In Gantry 1, change the Y value of "When Front Feeder Change Button Pressed" from 550 → 540.