EN 3.pdf - 第238页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.12 MMI V ersion 01 Tit le MMI IO CHECK(INPU T) Page 3-12-16 Note Check operation of the Front/Rear Jog Box Emer gency Switch. Press the Front/Rear T each ing box Emer…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.12 MMI
Version
01
Title
MMI IO CHECK(INPUT)
Page
3-12-15
Note
Check air pressure operation.
When the Main Air Pressure Gauge is below 0.4, an alarm occurs in the equipment. Now, check if the input
operates properly and when the value returns to 0.45, see if the I/O detection is released.
Check operation of the Front Safe Guard Key.
Press the Front Safe Guard Key and see if the input operates properly.
Check operation of the Feeder Gap Sensor.
Operate the Front/Rear Feeder Gap Sensor to see if the input operates properly.
Check operation of the Front/Rear Jog Box.
Attach the teaching box to the front/rear of the equipment and see if the input operates properly.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.12 MMI
Version
01
Title
MMI IO CHECK(INPUT)
Page
3-12-16
Note
Check operation of the Front/Rear Jog Box Emergency Switch.
Press the Front/Rear Teaching box Emergency Stop Switch to see if the input operates properly.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.12 MMI
Version
01
Title
MOTOR IO CHECK
Page
3-12-17
Note
[MOTOR IO CHECK]
Motor IO Check preparation.
IN the MMI, select <Diagnosis> → <Motor I/O> to launch the <Motor Status> windows.
MMI LABEL
G1F-Y(+) FY-PL
G1F-Y(HOME) FY-HM
G1F-Y(-) FY-ML
G1R-Y(+) RY-PL
G1R-Y(HOME) RY-HM
G1R-Y(-) RY-ML
G1F-X(+) FX-PL
G1F-X(HOME) FX-HM
G1F-X(-) FX-ML
G1R-X(+) RX-PL
G1R-X(HOME) RX-HM
G1R-X(-) RX-ML
Motor IO Check
① Move the Y axis and check if the followings are detected: G1F-Y(+, Home, -), G1R-Y(+, Home, -)