EN 3.pdf - 第243页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.12 MMI V ersion 01 Tit le LIGHT CHECK Page 3-12-21 Note [LIGHT CHECK] Prepare for Light Check. In the MMI, select < Diagnosis> → <Light> to launch the <…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.12 MMI
Version
01
Title
MOTOR IO CHECK
Page
3-12-20
Note
Left Only Shuttle Conveyor (Shuttle - Dual - Dual)
Right Only Shuttle (Dual - Dual - Shuttle)

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.12 MMI
Version
01
Title
LIGHT CHECK
Page
3-12-21
Note
[LIGHT CHECK]
Prepare for Light Check.
In the MMI, select < Diagnosis> → <Light> to launch the <Camera Light Diagnosis > windows.
Check if the lighting of #1, #2, #3, #4 Fiducial Camera are changed.(#1, #3 are options.)
Adjust the Outer & Inner lighting values to visually check if the brightness is changed.
(Inner lighting is hard to check visually so use a mirror to check if the LED is lit.)
In the Vision windows, check if the output is normal.
There should be no noise, screen shaking/distortion or missing outputs.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.12 MMI
Version
01
Title
LIGHT CHECK
Page
3-12-22
Note
Check if the Fly Camera 1~10's brightness is changed.
Adjust the Outer & Side lighting values to visually check if the brightness is changed.
(Outer lighting is hard to check visually so use a mirror to check it.)
In the Vision windows, check if the output is normal.
There should be no noise, screen shaking/distortion or missing outputs.