EN 3.pdf - 第279页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.15 PC RACK V ersion 01 Tit le POWER SUPPL Y REPLACEMENT Page 3-15-10 Note [POWER SUPPL Y REPLACEMENT] 1. T urn off the PC and turn of f the Main Switch in the front of …

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.15 PC RACK
Version
01
Title
PC RACK CHECK
Page
3-15-9
Note
[PC RACK CHECK]
1. In the PC Rack, check the connector connection.
2. Check if the HDD Cooling Fan Operation Lamp is lit properly.
3. Check if the Power Supply has a high voltage warning sticker attached to it.
4. Check if the 24V P/S terminal board has an acryl cover attached to it.
5. From the left of the PC Rack, the order of assembly goes like the following: SBC Board, IT Master Board,
PCI Board, NT-A8 Board.
6. Check if the exterior is damaged.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.15 PC RACK
Version
01
Title
POWER SUPPLY REPLACEMENT
Page
3-15-10
Note
[POWER SUPPLY REPLACEMENT]
1. Turn off the PC and turn off the Main Switch in the front of the equipment.
2. Separate the front cover from the equipment.
3. Separate the cable from the PC Rack.
4. Release the fixing bolts for the PC Rack and separate the PC Rack.
5. Separate the Front Panel of the PC Rack and release the fixing bolts for the Power Supply to separate it.
6. Replace with a new Power Supply.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.15 PC RACK
Version
01
Title
COOLING FAN CHANGE
Page
3-15-11
Note
[COOLING FAN CHANGE]
1. Turn off the PC and turn off the Main Switch in the front of the equipment.
2. Separate the front cover from the equipment.
3. Separate the cable from the PC Rack.
4. Release the fixing bolts for the PC Rack and separate the PC Rack.
5. Separate the fan by releasing the fixing bolts for the fan in the bottom panel of the PC Rack.
6. Pay attention to the direction so that the new fan does not blow the wind out of the panel.