EN 3.pdf - 第289页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.16 X-FRAME V ersion 01 Tit le XY -DUCT X AXIS CABL E WIRING Page 3-16-8 Note XY Duct 's X Axis Cable W iring3 XY Duct 's X Axis Cable W iring4 Separate …

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
XY-DUCT X AXIS CABL E WIRING
Page
3-16-7
Note
[XY-DUCT X AXIS CABLE WIRING]
XY Duct's X axis Cable Wiring1
Push the Flat Cable to the opposite side and fix the belt.
XY Duct's X axis Cable Wiring2
Y Motor Unit Cable Wiring
As shown below, assemble the Y Motor Cable into the Connector of the Flat Cable from the bottom of the
Connector Bracket.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
XY-DUCT X AXIS CABL E WIRING
Page
3-16-8
Note
XY Duct's X Axis Cable Wiring3
XY Duct's X Axis Cable Wiring4
Separate the X-Frame Cable Cover and wire the cable.
Assemble the sensor on the X axis.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
XY-DUCT X AXIS CABL E WIRING
Page
3-16-9
Note
Y Axis Motor Cable Wiring
Linear-Scale Cable Wiring
X Axis Motor Cable Wiring
Ground Cable Wiring