EN 3.pdf - 第296页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.16 X-FRAME V ersion 01 Tit le X AXIS LM GUIDE BOL T REASSEMBL Y Page 3-16-15 Note [X AXIS LM GUIDE BOL T REASSEMBL Y] Fix the center and end bolts first and then fix …

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
LIMIT SENSOR REPLACEMENT
Page
3-16-14
Note
[LIMIT SENSOR REPLACEMENT]
1. Turn off the PC and turn off the Main Switch in the front of the equipment.
2. Separate the cable for the sensor you want to replace.
3. Remove the fixing bolts from the sensor.
4. Replace with a new sensor.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.16 X-FRAME
Version
01
Title
X AXIS LM GUIDE BOLT REASSEMBLY
Page
3-16-15
Note
[X AXIS LM GUIDE BOLT REASSEMBLY]
Fix the center and end bolts first and then fix other bolts.
Using a torque wrench, apply140kgf/cm.
After finishing assembly, check the degree of straightness.
The degree of straightness with respect to the Main Head Base should be less than 0.03.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.17 Y-FRAME
Total Pages
12
Table of Contents
[CONNECTOR PANEL ASSEMBLY] ................................................................... 2
[GREASE INJECTION] ........................................................................................ 3
[LINEAR SCALE FIRMWARE UPGRADE] .......................................................... 5
[Y AXIS NOISE DECISION CRITERIA] ............................................................... 6
[FLAT CABLE ASSEMBLY] ................................................................................. 7
[XY DUCT INSPECTION] .................................................................................... 8
[XY EXTERIOR CHECK] ..................................................................................... 9
[MOTOR DRIVER ASSEMBLY]......................................................................... 10
[LIMIT SENSOR REPLACEMENT] .................................................................... 12