EN 3.pdf - 第335页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.19 ELECTRIC DEVICE V ersion 01 Tit le MAIN POWER SHORT TEST Page 3-19-9 Note 8. Measure the insulation resistance/power at the AC 220V input and the DC 24V output. Meas…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
MAIN POWER SHORT TEST
Page
3-19-8
Note
6. Measure the insulation resistance between TB#1 and the Earth Plate.
Inspection units Inspection criteria
EARTH PLATE 의 SHORT CHECK : F.G , 1L1
100MΩ or higher or OPEN
EARTH PLATE 의 SHORT CHECK : F.G , 1L2
EARTH PLATE 의 SHORT CHECK : F.G , 22R
EARTH PLATE 의 SHORT CHECK : F.G , 22T
EARTH PLATE 의 SHORT CHECK : F.G , 22L1
EARTH PLATE 의 SHORT CHECK : F.G , 22L2
EARTH PLATE 의 SHORT CHECK : F.G , 22L3
*Condition : Short check between the earth terminal and the AC power.
7. Noise Filter resistance measurement
Inspection units Inspection criteria
NF#1 의 SHORT CHECK : NF1-R , NF1-S
600 ~ 750 kΩ
NF#1 의 SHORT CHECK : NF1-R , NF1-T
600 ~ 750 kΩ
NF#1 의 SHORT CHECK : NF1-S , NF1-T
600 ~ 750 kΩ
*Condition : MCCB ON, Main Power S/W OFF
Inspection units Inspection criteria
NF#1 의 SHORT CHECK : NF1-R , NF1-S
3Ω or less
NF#1 의 SHORT CHECK : NF1-R , NF1-T
3Ω or less
NF#1 의 SHORT CHECK : NF1-S , NF1-T
3Ω or less
*Condition : MCCB ON, Main Power S/W ON
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
MAIN POWER SHORT TEST
Page
3-19-9
Note
8. Measure the insulation resistance/power at the AC 220V input and the DC 24V output.
Measure the insulation resistance at the AC220V input.
Inspection units Inspection criteria
PS#1 AC input : L, N 900 ~ 1050KΩ
PS#2 AC input : L, N 900 ~ 1050KΩ
PS#3 AC input : L, N 900 ~ 1050KΩ
PS#4 AC input : L, N 900 ~ 1050KΩ
PS#5 AC input : L, N 900 ~ 1050KΩ
PS#6 AC input : L, N 900 ~ 1050KΩ
DC24V output's insulation resistance
Inspection units Inspection criteria
PS#1 DC output : +, - 900 ~ 1050KΩ
PS#2 DC output : +, - 900 ~ 1050KΩ
PS#3 DC output : +, - 900 ~ 1050KΩ
PS#4 DC output : +, - 900 ~ 1050KΩ
PS#5 DC output : +, - 900 ~ 1050KΩ
PS#6 DC output : +, - 900 ~ 1050KΩ
AC220V input power
Inspection units Inspection criteria
PS#1 AC input : L, N AC 220V±10
PS#2 AC input : L, N AC 220V±10
PS#3 AC input : L, N AC 220V±10
PS#4 AC input : L, N AC 220V±10
PS#5 AC input : L, N AC 220V±10
PS#6 AC input : L, N AC 220V±10
DC24V output power
Inspection units Inspection criteria
PS#1 DC output : +, - DC 24V±0.72
PS#2 DC output : +, - DC 24V±0.72
PS#3 DC output : +, - DC 24V±0.72
PS#4 DC output : +, - DC 24V±0.72
PS#5 DC output : +, - DC 24V±0.72
PS#6 DC output : +, - DC 24V±0.72
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
DC POWER SHORT CHECK
Page
3-19-10
Note
[DC POWER SHORT CHECK]
1. Safety Control Board Dip Switch setting check.
SWITCH DIP SWITCH SETTING
1 No.1,2 : ON
2. Measure the CN1/2 insulation resistance of the Safety Control Board.
Inspection units Inspection criteria
CN1-1 , CN1-3
100MΩ or higher or OPEN
CN2-1 , CN2-3
* Condition : Separate the connector from CN1,CN2.