EN 3.pdf - 第340页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.19 ELECTRIC DEVICE V ersion 01 Tit le VOL T AGE CHECK TEST Page 3-19-14 Note Inspection units Inspection criteria Front MONITOR power measurement : 220L, 220N AC 220V±1…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-13
Note
11. Motor Driver Control Power(FY1,FY2,RY1, RY2FX,RX,FSW,RSW) measurement.
Inspection units Inspection criteria
MOTOR DRIVER CONTROL POWER FS axis X1 : 1(FS-t) , 2(FS-r)
AC 220V±10
MOTOR DRIVER CONTROL POWER FX axis X1 : 1(FX-t) , 2(FX-r)
MOTOR DRIVER CONTROL POWER RS axis X1 : 1(RS-t) , 2(RS-r)
MOTOR DRIVER CONTROL POWER RX axis X1 : 1(RX-t) , 2(RX-r)
MOTOR DRIVER CONTROL POWER FY1 axis X1 : 1(FY1-t) , 2(FY1-r)
MOTOR DRIVER CONTROL POWER FY2 axis X1 : 1(FY2X-t) , 2(FY2-r)
MOTOR DRIVER CONTROL POWER RY1 axis X1 : 1(RY1-t) , 2(RY1-r)
MOTOR DRIVER CONTROL POWER RY2 axis X1 : 1(RY2-t) , 2(RY2-r)
12. FAN #1~8, Front/Rear Monitor, PC Rack power are measured in the following order.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-14
Note
Inspection units Inspection criteria
Front MONITOR power measurement : 220L, 220N
AC 220V±10
Rear MONITOR power measurement : 220L, 220N
FAN #1 power measurement : FAN1 - 1,2
FAN #2 power measurement : FAN2 - 1,2
FAN PUMP power measurement : FAN PUMP - 1,2
FAN #3 power measurement : FAN3 - 1,2
FAN #4 power measurement : FAN4 - 1,2
FAN #7 power measurement : FAN3 - 1,2
FAN #8 power measurement : FAN4 - 1,2
SERVO FAN LEFT power measurement : FAN5 - 1,2
SERVO FAN RIGHT power measurement : FAN6 - 1,2
*Condition : CP#1 ON, CP#2 ON
13. MCCB power measurement
Inspection units Inspection criteria
MCCB : 1,3
AC 220V±10
MCCB : 1,5
MCCB : 3,5
*Condition : CP#1 OFF, CP#2 OFF, CP#3 OFF, MCCB, Main Power Switch OFF

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-15
Note
14. Noise Filter resistance measurement
Inspection units Inspection criteria
NOISE FILTER : NF1-R , NF1-S
AC 220V±10
NOISE FILTER: NF1-R , NF1-T
NOISE FILTER: NF1-S , NF1-T
*Condition : MCCB ON, Main Power Switch OFF
15. DC Power Supply power measurement
Inspection units Inspection criteria
#1 DC POWER SUPPLY : PS1+24V, PS1-24G
DC 24.30±0.05V
#2 DC POWER SUPPLY : PS1+24V, PS1-24G
#3 DC POWER SUPPLY : PS1+24V, PS1-24G
#4 DC POWER SUPPLY : PS1+24V, PS1-24G
#5 DC POWER SUPPLY : PS1+24V, PS1-24G
#6 DC POWER SUPPLY : PS1+24V, PS1-24G
*Condition : CP#1 ON, CP#2 ON, CP#3 ON
AC/DC power activated when the Safety Control Board CN1,CN2 is accessed.
1. Turn CP#1,2,3 off.
2. Connect the CN1/2 connector to the Safety Control Board.