EN 3.pdf - 第341页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.19 ELECTRIC DEVICE V ersion 01 Tit le VOL T AGE CHECK TEST Page 3-19-15 Note 14. Noise Filter resistance measurement Inspection units Inspection criteria NOISE FIL TER …

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-14
Note
Inspection units Inspection criteria
Front MONITOR power measurement : 220L, 220N
AC 220V±10
Rear MONITOR power measurement : 220L, 220N
FAN #1 power measurement : FAN1 - 1,2
FAN #2 power measurement : FAN2 - 1,2
FAN PUMP power measurement : FAN PUMP - 1,2
FAN #3 power measurement : FAN3 - 1,2
FAN #4 power measurement : FAN4 - 1,2
FAN #7 power measurement : FAN3 - 1,2
FAN #8 power measurement : FAN4 - 1,2
SERVO FAN LEFT power measurement : FAN5 - 1,2
SERVO FAN RIGHT power measurement : FAN6 - 1,2
*Condition : CP#1 ON, CP#2 ON
13. MCCB power measurement
Inspection units Inspection criteria
MCCB : 1,3
AC 220V±10
MCCB : 1,5
MCCB : 3,5
*Condition : CP#1 OFF, CP#2 OFF, CP#3 OFF, MCCB, Main Power Switch OFF

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-15
Note
14. Noise Filter resistance measurement
Inspection units Inspection criteria
NOISE FILTER : NF1-R , NF1-S
AC 220V±10
NOISE FILTER: NF1-R , NF1-T
NOISE FILTER: NF1-S , NF1-T
*Condition : MCCB ON, Main Power Switch OFF
15. DC Power Supply power measurement
Inspection units Inspection criteria
#1 DC POWER SUPPLY : PS1+24V, PS1-24G
DC 24.30±0.05V
#2 DC POWER SUPPLY : PS1+24V, PS1-24G
#3 DC POWER SUPPLY : PS1+24V, PS1-24G
#4 DC POWER SUPPLY : PS1+24V, PS1-24G
#5 DC POWER SUPPLY : PS1+24V, PS1-24G
#6 DC POWER SUPPLY : PS1+24V, PS1-24G
*Condition : CP#1 ON, CP#2 ON, CP#3 ON
AC/DC power activated when the Safety Control Board CN1,CN2 is accessed.
1. Turn CP#1,2,3 off.
2. Connect the CN1/2 connector to the Safety Control Board.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.19 ELECTRIC DEVICE
Version
01
Title
VOLTAGE CHECK TEST
Page
3-19-16
Note
3. Connect a tool connector.
4. Turn CP#1,2,3 on.
5. Conveyor Belt Driver power measurement
Inspection units Inspection criteria
SM471 PW120-2 CABLE BS1-CN1 1,2, BS2-CN2 1,2 DC 24V±0.72
*Condition : Press MC#1.
Inspection units Inspection criteria
SM471 PW121-2 DC POWR BOARD power CN1 1,3
DC 24V±0.72
SM471 PW121-2 DC POWR BOARD power CN1 2,4
Inspection units Inspection criteria
FR DRV POWR BOARD power R-DRV-PW 1<-> 2
DC 24V±0.72
RR DRV POWR BOARD power R-DRV-PW 1<-> 2
6. Feeder Base Board Input power measurement
Inspection units Inspection criteria
FRONT LEFT FEEDER BASE B/D F-FB-L 1<->2
DC 24V±0.72
FRONT LEFT FEEDER BASE B/D F-FB-L 3<->4
FRONT RIGHT FEEDER BASE B/D F-FB-R 1<->2
FRONT RIGHT FEEDER BASE B/D F-FB-R 3<->4
REAR LEFT FEEDER BASE B/D R-FB-L 1<->2
REAR LEFT FEEDER BASE B/D R-FB-L 3<->4
REAR RIGHT FEEDER BASE B/D R-FB-L 1<->2
REAR RIGHT FEEDER BASE B/D R-FB-L 3<->4