EN 3.pdf - 第56页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.4 CAMERA V ersion 01 Tit le FIDUCIAL C AMERA OP TION SETTING Page 3-4-5 Note [FIDUCIAL CAMERA OPTION SETTING] If the equipment uses two Fiducial Cameras, then go to the…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.4 CAMERA
Version
01
Title
CAMERA LIGHTING CHECK
Page
3-4-4
Note
Fix Camera
- Select Fly Cam 1 and adjust the Light Value to see if the Side, Outer, and Inner LED starts turning on.
In the MMI's "Sys.Setup > Camera" set the basic Light Value.
Camera Light Default Value
Fiducial
Outer 7
Inner 7
Camera Light Default Value
Fly
Side 7
Outer 7
Coaxial 7
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.4 CAMERA
Version
01
Title
FIDUCIAL CAMERA OPTION SETTING
Page
3-4-5
Note
[FIDUCIAL CAMERA OPTION SETTING]
If the equipment uses two Fiducial Cameras, then go to the MMI and enable two cameras.
System Setup > Fly Camera
- If the same option is used, select Gantry 2 in <Gantry 2> and then select Fid Cam Use.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.4 CAMERA
Version
01
Title
STAGE CAMERA ENABLE
Page
3-4-6
Note
[STAGE CAMERA ENABLE]
If a Stage Camera is used, then set the following in the MMI.
1. In the MMI's <Sys. Setup> menu, access the Factory mode.
ID: MARKFAC, Password: MARKFACTORY
2. In <System Constant>, enable OPT_CALIBRATION_METHOD.
0: Stage Camera enabled.
1: Stage Camera disabled.