EN 3.pdf - 第6页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.1 ANC V ersion 01 Tit le SHUTTER CYLINDER REPLACEM ENT Page 3-1-4 Note [SHUTTER CYLINDER REPLACEMENT] 1. Power off the equipm ent. 2. Block the air pressure supplied to…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
ANC TOP FLATNESS CRITERIA
Page
3-1-3
Note
[ANC TOP FLATNESS CRITERIA]
ANC top's flatness criteria: 0.05mm or less.
Attach a Magnetic indicator(minimum scale of 2 um) to the head and check the degree of flatness.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
SHUTTER CYLINDER REPLACEM ENT
Page
3-1-4
Note
[SHUTTER CYLINDER REPLACEMENT]
1. Power off the equipment.
2. Block the air pressure supplied to the equipment.
3. Separate the air pressure tube and the cable connected to the ANC's Cylinder.
4. Release the fixing bolts for the cylinder and separate the cylinder.
5. Replace with a new cylinder.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
SHUTTER OPERATION SPEED SETTING
Page
3-1-5
Note
[SHUTTER OPERATION SPEED SETTING]
1. Run MMI and run Diagnosis> IO> Cylinder Check.
2. Click on Automatic to check the cylinder operation speed for each item.
No. Item Reference value
1 Shutter Open speed 70~90msec
2 Shutter Close speed 50~70msec
3. Turn the Speed Controller to set the operational speed.
- CW: speed reduction.
- CCW: speed increased.
* Checkpoint
Check if each cylinder operates properly.
Check if the Cylinder Up/Down spec is met.
Check for noises or mechanical interferences during ANC operation.