Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
CONVEYOR PCB GUIDE HEIGHT CRITERIA
Page
3-5-4
Note
[CONVEYOR PCB GUIDE HEIGHT CRITERIA]
Tool: Height gauge (minimum scale: 2um)
Criteria: -0.15 ~ 0.15 mm
Measurement location: all over the PCB Guide.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
CONVEYOR DIRECTION C HANGE(MMI)
Page
3-5-5
Note
[CONVEYOR DIRECTION CHANGE(MMI)]
1. In the MMI's <Sys. Setup> menu, access the Factory mode.
ID: MARKFAC, Password: MARKFACTORY
2. Set the Conveyor option in the <Factory Setting Option>
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
CONVEYOR DIRECTION C HANGE(MMI)
Page
3-5-6
Note
3. In the <Diagnosis → I/O → I/O Status>menu, check sensor operation.
4. In the <Sys.Setup → Conveyor>menu, check the Place Stopper X coordinate.
5. When performing loading tests on the PCB (max, min size), see if there is shaking or if it is stuck.