EN 3.pdf - 第69页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.5 CONVEYOR V ersion 01 Tit le CONVEYOR DIRECTION C HAN GE(MMI) Page 3-5-6 Note 3. In the <Diagnosis → I/O → I/O Status>menu, check sensor operation. 4. In the &lt…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
CONVEYOR DIRECTION C HANGE(MMI)
Page
3-5-5
Note
[CONVEYOR DIRECTION CHANGE(MMI)]
1. In the MMI's <Sys. Setup> menu, access the Factory mode.
ID: MARKFAC, Password: MARKFACTORY
2. Set the Conveyor option in the <Factory Setting Option>
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
CONVEYOR DIRECTION C HANGE(MMI)
Page
3-5-6
Note
3. In the <Diagnosis → I/O → I/O Status>menu, check sensor operation.
4. In the <Sys.Setup → Conveyor>menu, check the Place Stopper X coordinate.
5. When performing loading tests on the PCB (max, min size), see if there is shaking or if it is stuck.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
CONVEYOR DIRECTION C HANGE(MMI)
Page
3-5-7
Note
* Checkpoint
In the MMI, set the Conveyor Option.
After changing the conveyor direction, perform a conveyor operation test. (lasting more than 3 hours)
When operating the Entry Zone, Work Zone, or Exit Zone Belt, there should be no noises or malfunctions.
Check the sensor assembly location and there should be no sensor malfunctions on the I/O.
Conveyor's Place Stopper X coordinate should be correct.
When you perform max/min PCB loading tests, there should be no shaking or jams.