EN 3.pdf - 第7页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.1 ANC V ersion 01 Tit le SHUTTER OPERA TIO N SPEED SETTING Page 3-1-5 Note [SHUTTER OPERA TION SPEED SETTING] 1. Run MMI and run Diagnosis> IO> Cylinder Check. 2.…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
SHUTTER CYLINDER REPLACEM ENT
Page
3-1-4
Note
[SHUTTER CYLINDER REPLACEMENT]
1. Power off the equipment.
2. Block the air pressure supplied to the equipment.
3. Separate the air pressure tube and the cable connected to the ANC's Cylinder.
4. Release the fixing bolts for the cylinder and separate the cylinder.
5. Replace with a new cylinder.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
SHUTTER OPERATION SPEED SETTING
Page
3-1-5
Note
[SHUTTER OPERATION SPEED SETTING]
1. Run MMI and run Diagnosis> IO> Cylinder Check.
2. Click on Automatic to check the cylinder operation speed for each item.
No. Item Reference value
1 Shutter Open speed 70~90msec
2 Shutter Close speed 50~70msec
3. Turn the Speed Controller to set the operational speed.
- CW: speed reduction.
- CCW: speed increased.
* Checkpoint
Check if each cylinder operates properly.
Check if the Cylinder Up/Down spec is met.
Check for noises or mechanical interferences during ANC operation.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
SHUTTER SENSOR ADJUSTMENT
Page
3-1-6
Note
[SHUTTER SENSOR ADJ USTMENT]
1. Close the shutter and move the close detection sensor and meanwhile check if the sensor light is on.
(Check the detection range of the sensor in the bottom)
2. Move it by 1 mm from right to left of the close detection and then assemble it.
3. Open the shutter and move the open detection sensor and meanwhile check if the sensor light is on.
(Check the detection range of the sensor in the top)