EN 3.pdf - 第73页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.5 CONVEYOR V ersion 01 Tit le EDGE FIXER OPER A TION CHECK Page 3-5-10 Note [EDGE FIXER OPERA TION CHECK] 1. In the <Diagnosis → I/O Status> menu, check operation…

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
CONVEYOR OPTION CHANGE(MMI)
Page
3-5-9
Note
4. Conveyor option selection
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
EDGE FIXER OPERATION CHECK
Page
3-5-10
Note
[EDGE FIXER OPERATION CHECK]
1. In the <Diagnosis → I/O Status> menu, check operation of the Edge Fixer.
2. Check if the Edge Fixer Regulator's air pressure is changed to “0.2”.
* Checkpoint
During I/O operation, see if the Edge Fixer operates properly.
When loading the max/min PCB suitable for the equipment spec, there should be no shaking or jams.
Edge Fixer Regulator should be securely fixed without shaking.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
EDGE FIXER CONNEC TION CHECK
Page
3-5-11
Note
[EDGE FIXER CONNECTION CHECK]
- The Conveyor's Work Zone Harness Assy should have six solenoid values on the two sides.
- Check the edge fixer assembly in the Work Zone.