EN 3.pdf - 第8页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.1 ANC V ersion 01 Tit le SHUTTER SENSOR ADJUSTMENT Page 3-1-6 Note [SHUTTER SENSOR ADJ USTM ENT] 1. Close the shutter and move the close detection senso r and meanwhile…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
SHUTTER OPERATION SPEED SETTING
Page
3-1-5
Note
[SHUTTER OPERATION SPEED SETTING]
1. Run MMI and run Diagnosis> IO> Cylinder Check.
2. Click on Automatic to check the cylinder operation speed for each item.
No. Item Reference value
1 Shutter Open speed 70~90msec
2 Shutter Close speed 50~70msec
3. Turn the Speed Controller to set the operational speed.
- CW: speed reduction.
- CCW: speed increased.
* Checkpoint
Check if each cylinder operates properly.
Check if the Cylinder Up/Down spec is met.
Check for noises or mechanical interferences during ANC operation.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
SHUTTER SENSOR ADJUSTMENT
Page
3-1-6
Note
[SHUTTER SENSOR ADJ USTMENT]
1. Close the shutter and move the close detection sensor and meanwhile check if the sensor light is on.
(Check the detection range of the sensor in the bottom)
2. Move it by 1 mm from right to left of the close detection and then assemble it.
3. Open the shutter and move the open detection sensor and meanwhile check if the sensor light is on.
(Check the detection range of the sensor in the top)

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.1 ANC
Version
01
Title
ANC AIR PRESS URE LINE WIRING (F2)
Page
3-1-7
Note
[ANC AIR PRESSURE LINE WIRING (F2)]
Front ANC
Using the air pressure tube connected to the Conveyor Assy, make a connection to the ANC cylinder.
- Blue : connected to the cylinder shutter.
- Black : connected to the sensor in the rear of the cylinder.