EN 3.pdf - 第92页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.5 CONVEYOR V ersion 01 Tit le SENSOR REPLACEMENT Page 3-5-29 Note [SENSOR REPLACEMENT] ① Entry Zone Width Detecting Sensor ② Front Conveyor W ork Zone W idth Detecting …

100%1 / 355
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
LEAD SCREW & LM GUIDE CLEANING A ND
FUEL INJECTION
Page
3-5-28
Note
[LEAD SCREW & LM GUIDE CLEANING AND FUEL INJECTION]
Clean the Lead Screw & the LM Guide.
Inject grease into the Lead Screw & the LM Guide.
-Using a brush, apply grease to the Lead Screw and the LM Guide Rail.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
SENSOR REPLACEMENT
Page
3-5-29
Note
[SENSOR REPLACEMENT]
① Entry Zone Width Detecting Sensor
② Front Conveyor Work Zone Width Detecting Sensor
③ Work Zone Width Detecting Sensor
④ Exit Zone Width Detecting Sensor
① Entry Sensor
② Front Conveyor Work Sensor1
③ Front Conveyor Work Sensor2
④ Rear Conveyor Work Sensor1
⑤ Rear Conveyor Work Sensor2
⑥ Exit Sensor
⑦ PCB Out detecting Sensor
1. Separate the cable connected to the sensor.
2. Separate the old sensor and replace it with a new one.
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.5 CONVEYOR
Version
01
Title
STOPPER CYLINDER REPLACEMENT
Page
3-5-30
Note
[STOPPER CYLINDER REPLACEMENT]
Assemble the Stopper Cylinder.
Pay attention to the direction of the Stopper Top Plate when you assemble it.
Assemble the Stopper Sensor.
Make sure that the Up Sensor is on the Entry side.
The Up Sensor Down Sensor's LED On region is displayed.
Give one I marking on the top of the sensor.