EN 3.pdf - 第97页
Model DECAN Series Company SAMSUNG TECHWIN Module 3.6 COVER V ersion 01 Tit le SAFETY SENSOR OPERA TION CHECK(MMI) Page 3-6-3 Note 3. In the <Diagnosis → I/O → I/O Status>menu, check sensor operation. 4. While the …

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.6 COVER
Version
01
Title
SAFETY SENSOR OPERATION CHECK(MMI)
Page
3-6-2
Note
[SAFETY SENSOR OPERATION CHECK(MMI)]
1. In the MMI's <Sys. Setup> menu, access the Factory mode.
ID: MARKFAC, Password: MARKFACTORY
2. In the <Factory Constants>menu, check the <OPT AREA SENSOR> setting. (If you use this function, set it
to "1".)

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.6 COVER
Version
01
Title
SAFETY SENSOR OPERATION CHECK(MMI)
Page
3-6-3
Note
3. In the <Diagnosis → I/O → I/O Status>menu, check sensor operation.
4. While the equipment is operating, if the safety sensor detects an object, check whether the equipment stops
and an error occurs.
* Checkpoint
- Check the location of safety sensor
Front Rear
Left Light emission(EMITTER) Left Light emission(EMITTER)
Right Light receiving(RECEIVER) Right Light receiving(RECEIVER)
- When the equipment operates, if the safety sensor detects an object, the ready lamp will be turned off and
the error message will say " Safety sensor detection".
- Scratches, dents, wirings.

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.6 COVER
Version
01
Title
MONITOR INSTALLATION
Page
3-6-4
Note
[MONITOR INSTALLATION]
1. Slightly bend the middle part of the monitor bracket and attach it with the bracket arm to the monitor.
2. After attaching the monitor to the equipment, connect the signal and power cables.