LBO 27 Zoll - 第49页
LBO 27" 2 Assembly instructions LBO 27" SIPLACE X4 09/2007 Edition 49 2 Assembly instructions LBO 27" SIPLACE X4 2.1 Function principle The special design LBO 27” can only be used together with the special…

1 Montageanleitung 27" SIPLACE X4 LBO 27"
Ausgabe 09/2007
48
1.11 Plan
1
Abb. 1.6 - 1 Plan Verkabelung Stopper
LBO 27" 2 Assembly instructions LBO 27" SIPLACE X4
09/2007 Edition
49
2 Assembly instructions
LBO 27" SIPLACE X4
2.1 Function principle
The special design LBO 27” can only be used together with the special design 00176092-xx. 2
The delivered units for processing area 1 (PA1) and processing area 2 (PA2) are pre-assembled
for installation in machines with the stationary conveyor side wall on the right. 2
2.2 Requirements
Hardware: X4, (Single-conveyor, stationary conveyor side wall on right) 2
Software: 603.24IN-01.47.1 2
2.3 Restrictions
– The minimum PCB-width with the LBO 27” is about 240 mm.
– The minimum PCB-thickness is 2,5 mm.
– The maximum PCB-thickness is 6,5 mm.
– The maximum PCB-bowing is 0,5 mm.
– The maximum component height on the bottom side of the PCB is 21 mm.
– In combination with the special design the restrictions concerning the PCB-barcode still apply.
– The cycle-time delays about 2 seconds per PCB during to the slower conveyor-velocity.
– The lifetime of the conveyor-belts will decrease because of the higher PCB-weight.
2
2
2
2
2
2
2
2
2 Assembly instructions LBO 27" SIPLACE X4 LBO 27"
09/2007 Edition
50
2.4 Scope of delivery
– Product license (00373251)
– 1 stopper unit for PA1 pre-assembled with cable loom
– 1 stopper unit for PA2 pre-assembled with cable loom
– 2 Tee connectors for PUN 6 hose (with short piece of hose)
– 4 hexagon socket screws M6 x 40 mm
– 2 connecting cable sets (00372253-01)
– 1 hose PUN 6 with quick lock short (120 mm)
– 1 hose PUN 6 with quick lock long (2140 mm)
– Test-PCB for stopper adjustment (236 mm length)
– Cable ties
– Cable clips small
– Cable clips returnable
– Hyperterminal CD
2
2