7.2 SX1/SX2 placement machine
For the SX1/SX2 placement machine the following window is displayed, in which the Manual selection
required note informs, that the table configuration has to be selected manually, as this is not detected
automatically.
Fig. 7-5: Selecting table configuration
→ Click the ? question mark next to Location 2.
The selectable table configurations are displayed.
Fig. 7-6: Possible table configurations
→ Select a table configuration with or .
→ Click the Accept button.
48 of 60

Installation Manual, Station Software Version 704.01 04/2010 Edition
→ Repeat the steps for Location 1.
When you have selected all table configurations the following window is displayed, in which you confirm
the Auto-configuration.
Fig. 7-7: Confirming Auto-configuration for SX1/SX2
→ Click the Confirm changes and continue startup button to confirm the Auto-configuration.
7.3 SX+ placement machine
If the SX+ placement machine is to be used without gantries, this has to be configured in the Auto-
configuration after the machine has been booted. For this you have to select "Ignore gantries" at the
processing area in the machine configuration dialog.
7.4 SX4 placement machine
When the SX4 placement machine is booted for the first time you have to select the "SX4 High Speed"
entry for "Machine frame" manually in the Auto-configuration, if there are tables in outer position in
processing area 2, as this is not detected automatically via sensors. Tables in outer position are used
when stationary cameras are in use. Otherwise you select the "SX4 Speed" entry.
49 of 60
Installation Manual, Station Software Version 704.01 04/2010 Edition
50 of 60
7.5 Checking/Updating the embedded software
If the correct eSW versions are not available on the machine, the machine boot gets interrupted.
→ In this case, perform an eSW download.
→ Start an overall reference run for the machine.
7.6 Storage location of the machine files (calibration data etc.)
The machine-specific configuration, measurement and parameter data is stored in XML files under
C:\Sirio\Work\Individual. These XML files contain all the calibration data.