3.1 "Transfer Mode Set-up" Tab
3.1 "Transfer Mode Set-up" Tab
Sheet Layout
When the [Transfer Mode Set-up] tab on the "DEVICE DATA"
window (submenu) is pressed, the following tab sheet appears.
Fig. 3D13 "Transfer Mode Set-up" Tab Sheet
Sheet Composition
*1 Input Mode
Select one of the option buttons to determine the way how to
receive P.C.B.’s from the input machine.
Standard/Sub-Standard :
The machine receives the P.C.B.’s discharged
from the input machine.
The L conveyor is activated when a P.C.B.
transfer signal is received from the input
machine.
Pusher : The machine receives P.C.B.’s discharged
forcibly by the pusher from the input machine.
Turn on the desired option button. A dot appears inside
the circle, indicating that the desired item is selected.
*1
*2
*3
*4
*5
Tg0699-PM-D2
*2 Output Mode
It can be selected how to discharge P.C.B.’s to the output machine.
Standard : This machine turns on the P.C.B. transfer signal in re-
sponse to a P.C.B. requirement signal transmitted from
the output machine and keeps on discharging P.C.B.’s
until the P.C.B. requirement signal is turned off.
When the P.C.B. requirement signal is not turned off
within the specified time after this machine has started
discharging P.C.B.’s, the machine stops running in an
error condition.
Interval : This machine turns on a P.C.B. transfer signal in re-
sponse to a P.C.B. requirement signal transmitted from
the output machine and activates the conveyor to dis-
charge P.C.B.’s for the specified period of time.
*3 Hold P.C.B.
It can be determined whether or not P.C.B.'s should be retained on
the L conveyor, the table chute, and the R conveyor.
3P (Standard) : Three pieces of P.C.B.'s are retained on the
L conveyor, the table chute, and the R con-
veyor.
2P : Two pieces of P.C.B.'s are retained on the L
conveyor and the table chute.
1P : A P.C.B. is retained on the L conveyor. It is
printed and discharged when a P.C.B. re-
quirement signal from the output machine is
"ON".
(a) Select "2P" to prevent any foreign substances from
adhering to a printed P.C.B. on the R conveyor.
(b) When "1P" is selected, the P.C.B. on the R conveyor
is not transferred onto the table chute when a P.C.B.
requirement signal from the output machine is "OFF".
*4 Auto Run/Stop
It can be determined whether or not the machine should be started
or stopped automatically.
When you turn on the desired check box, a check mark (;) ap-
pears inside the box, indicating that the function is selected.
0207-001 Chapter 1 4-20
3.1 "Transfer Mode Set-up" Tab
Tg0699-PM-D2
Auto Stop Mode: When this mode is selected, the machine auto-
matically stops running in the following case A
or B.
A. The machine stops running based on the fol-
lowing criteria.
1) There is no P.C.B. inside the machine.
2) The machine is waiting for a P.C.B. to be
transferred from the input machine and
more than 2 seconds has elapsed since
the "RUN" signal of the input machine is
turned off.
B. The machine stops running based on the
following criteria
1) There is no P.C.B. inside the machine.
2) The input machine is stopped.
Auto Line Start Mode : When this mode is selected and the out-
put machine starts the automatic opera-
tion, this machine is interlocked and also
starts its automatic operation.
This function does not work while the screen saver func-
tion is activated.
Auto Line Stop Mode : When this mode is selected and the out-
put machine stops the automatic opera-
tion, this machine is interlocked and also
stops its automatic operation.
*5 Timer Setting (sec)
It can be determined how many seconds are required for the input
and output conveyors to be activated to receive a P.C.B. from the
input machine and discharge a P.C.B. to the output machine.
Input Conveyor : Enter the operating time of the input conveyor
in the text box.
Approximately 2 seconds must be added to
the time required to receive a P.C.B. from the
input machine and the total time must be en-
tered.
Output Conveyor : Enter the operating time of the output con-
veyor in the text box.
Approximately 2 seconds must be added to
the time required to discharge a P.C.B. to the
output machine and the total time must be en-
tered.
0207-001 Chapter 1 4-21
3.1 "Transfer Mode Set-up" Tab